MadgeTech Therm-A-lert Product User Manual

MadgeTech Therm-A-lert Product User Manual

Wireless temperature data logger

Advertisement

Quick Links

Therm•A•lert
Wireless Temperature Data Logger
Product User Guide

Advertisement

Table of Contents
loading

Summary of Contents for MadgeTech Therm-A-lert

  • Page 1 Therm•A•lert Wireless Temperature Data Logger Product User Guide...
  • Page 2: Table Of Contents

    Product User Guide Table of Contents Quick Start Steps ............. 3 Product Overview ............ 4 Software Installation ..........5 Activating & Deploying the Data Logger....6 Channel Programming ..........7 Product Maintenance ..........8 RMA Instructions ............8 Troubleshooting ............9 Compliance Information ........
  • Page 3: Quick Start Steps

    To activate the wireless mode, flip the black switch on the back of the Therm•A•lert to the 'On' position. (0 is 'Off', 1 is 'On'). Launch the MadgeTech 4 Software. All active MadgeTech data loggers that are within range will automatically appear in the Connected Devices window.
  • Page 4: Product Overview

    The system can be used to monitor a single location, or expanded to monitor hundreds of locations over a broad area (additional MadgeTech wireless loggers and transceivers may be required).
  • Page 5: Software Installation

    Transmit real-time data to the MadgeTech Cloud Services platform via the MadgeTech Data Logger Software running on a central PC or transmit directly to the MadgeTech Cloud without a PC using the MadgeTech RFC1000 Cloud Relay (sold separately).
  • Page 6: Activating & Deploying The Data Logger

    To activate the wireless mode, flip the black switch on the back of the Therm•A•lert to the 'On' position. (0 is 'Off', 1 is 'On'). On the Windows PC, launch the MadgeTech 4 Software. All active data loggers will be listed in the Device tab within the Connected Devices panel, showing that the data loggers are recognized.
  • Page 7: Channel Programming

    Different wireless channels may be used to create multiple networks in one area, or to avoid wireless interference from other devices. Any MadgeTech data logger or RFC1000 wireless transceiver that is on the same network is required to use the same channel. If all of the devices are not on the same channel, the devices will not communicate with one another.
  • Page 8: Product Maintenance

    RMA Instructions To send a device back in to MadgeTech for calibration, service or repair, follow the instructions below to create an RMA (Return Merchandise Authorization) on the MadgeTech website: Go to www.madgetech.com/rma.
  • Page 9: Troubleshooting

    » Ensure that the MadgeTech 4 Software is being used, and that no other MadgeTech Software (such as MadgeTech 2, or MadgeNET) is open and running in the background. MadgeTech 2 and MadgeNET are not the compatible with the RFRHTemp2000A.
  • Page 10: Compliance Information

    Product User Guide Compliance Information This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. To satisfy FCC RF Exposure requirements for mobile and base station transmission devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during operation.
  • Page 11: General Specifications

    Date and time stamped °C, °F, K, °R Time Accuracy ±1 minute/month (at 25 °C) PC Compatibility MadgeTech 4: Windows 10, 8, 7, Vista, Window XP with SP3 MadgeTech Cloud Services Compatible Operating Environment -20 °C to +80 °C (-4 °F to +176 °F) 0 %RH to 95 %RH non-condensing Dimensions 2.2 in x 5.25 in x 1.3 in (55 mm x 133 mm x 33 mm)
  • Page 12 DOC-1224036-00 REV 7 2016.04.26...

Table of Contents