Specifications - Redarc Manager15 Manual

Battery management system
Table of Contents

Advertisement

1
INTRODUCTION
1.4
Specifications
Electrical Specifications
Inputs
AC Input
Input Voltage Range (nominal)
Power Rating
Efficiency
Connection
DC Input
Input Voltage Range
Maximum Input Current Rating
Turn ON/OFF Threshold 12V (24V)
Power Rating
Typical Efficiency
Connection
Solar Input
Input Voltage Range
Maximum Input Current Rating
Turn ON (Open Circuit Voltage)
Power Rating
Typical Efficiency
Connection
Max Charging Volts @ Battery Terminals
Gel Setting
AGM Setting
Calcium Setting
Standard Lead Acid Setting
Float Voltage
Output Current (Nominal)
Temperature Compensation
Unit Operating Temperature*
Over Temperature Shutdown
Total Battery Capacity
Output Battery Volts (Nominal)
Output Battery Volts (Minimum)
Maximum Current on Load Disconnect Wire
Memory Save on Battery Disconnect
Output Protection
Short Circuit Protection
Surge Protection
Reverse Polarity Protection
Overload Protection
Compliance
CE
Safety
Environmental
General Specifications
Main Unit Dimensions
Remote Dimensions
Kit Weight
Warranty
* The Manager15 will only charge the battery when the battery temperature is between 0°C and 60°C in order to protect the
battery from damage.
Storage Mode
6
220-240VAC 50Hz
280W
80% - 90%
IEC Mains Plug
9 - 32V
30A
13.2V/12.7V (26.4V/25.4V)
260W
94%
Phoenix 1967498 Connector
9 - 32V
30A
17.5V
260W
93%
Phoenix 1967498 Connector
Touring Mode
14.4V
14.4V
14.4V
14.4V
16.0V
15.2V
15.5V
14.8V
13.5V
13.5V
15A
-30mV / °C
-40°C - 80°C
Yes
40 - 800Ah
12V
4V
1A
Yes
Yes
Yes
Yes
Yes
2009/19/EC
2009/104/EC
IEC60335
RoHS Compliant
445x185x79mm
186x74x29mm
5.5kg
2 years

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bms1215s3

Table of Contents