2
INSTALLATION GUIDE

2.4.3 Connecting the Battery Sensor

Wire the Battery Sensor as shown in figure 2.4.1.1 ensuring that the "BNEG" stud
connects to the House Battery negative terminal and the "GND" stud connects to
the vehicle common ground point.
Connect the CANBus Connection cable, the cable with the RJ12 connector, to the
CANBus network via the T-Piece supplied (see figure 2.4.2). The CANBus Connection
cable should be connected to the T-Piece using the RJ12 Insert provided.
The Battery Positive Lead connects to the house battery positive terminal, this
lead measures voltage and temperature at the battery.
(cable lugs not supplied)
to Vehicle
Common
Ground

2.4.4 Wiring the Main Unit

Refer to Figure 2.4.1 for required connections and to Figure 2.4.2 typical setup.
1
2
3
AC
AC Mains Input
MAINS
NOTE: If a longer Remote Monitor cable is required, a replacement CAT5 patch
cable may be used, up to a length of 10m.
Figure 2.4.1.1 - Battery Sensor connections
CANBus Interface
Battery Output
Load Disconnect
Ground
Figure 2.4.1 - Required connections.
to Remote
Monitor
to House Battery
Negative Terminal
to House Battery
Positive Terminal
19
to Main
Unit
CAN Bus
Connection
DC Input
6
Solar Input
5
4
Ignition Trigger