Brymen BM079 User Manual page 20

Clamp-on multimeter series
Table of Contents

Advertisement

Capacitance (Models 079, 078, 076 & 073 only)
RANGE
200.0µF, 2500µF
1)
Accuracies with film capacitor or better
Diode Tester
RANGE
2.000V
Test Current: 0.3mA typically
Open Circuit Voltage: < 3.5VDC typically
DCµ µ µ µ A (Models 079 & 076 only)
RANGE
200.0µA, 2000µA
Temperature (Models 079 & 076 only)
RANGE
-40.0
o
C ~ 99.9
o
C
100
o
C ~ 400
o
C
-40.0
o
F ~ 211.8
o
212
o
F ~752
o
F
K-type thermocouple range & accuracy not included
TM
AmpTip
clamp-on ACA
RANGE
50Hz ~ 60Hz
60.00A
1)
Induced error from adjacent current-carrying conductor: <0.01A/A
2)
Specified with Relative Zero
if any
3)
Add 10d to the specified accuracy @ < 4A
4)
For Models 076, 073 & 072, unspecified @ <0.2A
F
mode applied to offset the non-zero residual readings,
Accuracy
1.0% + 5d
Accuracy
1)
2.0% + 4d
Accuracy
1.5% + 5d
Burden Voltage
3.5mV/µA
Accuracy
1.0% + 0.8
o
C
1.0% + 1
o
C
1.0% + 1.5
o
F
1.0% + 2
o
F
1) 2) 3) 4)
Accuracy
1.5% + 5d
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bm078Bm077Bm076Bm073Bm072

Table of Contents