2. PROCESSES AND FUNCTIONS

2-17 Auto-flap Control

Auto flap can control the air flow in 5 steps.
Operation mode
2
Cooling/dehumidifying
Standby for heating
(1) When the unit is stopped, the Auto-flap returns to F5 position.
(2) When the airflow direction is set (an optional setting), the auto and Swing settings will
be released. To return the mode to auto-flap control, change the operation mode.
(3) Once Auto-flap is set, the flap position will be input in the memory.
(4) When the operation mode is changed, the unit starts to search flap position. (if a
search action for sensing flap position is not succeeded in one minute, only the swing
is operated.)
F1
F2
Automatic setting
F2
Fan
F2
Heating
F4
F2 (The flap returns to the original position after
Cooling
Heating
F3
F4
F5
0677_M_I
Flap position
Optional setting
F1 • F2 • F3 • Swing
F1 • F2 • F3 • F4 • F5 • Swing
F1 • F2 • F3 • F4 • F5 • Swing
release of the standby mode.)