Page 1
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. SDAFM76R5I 387.106.994 SDAFM96R5I 387.106.995 SDAFM126R5I 387.106.996 SDAFM166R5I 387.106.997 SDAFM186R5I 387.106.998 SDAFM226R5I 387.106.999 0.8180.485.2 08/2008...
Page 2
IMPORTANT! • Ground the unit following local electrical codes. Please read before installation • The Yellow/Green wire cannot be used for any connection different from the ground connection. • Connect all wiring tightly. Loose wiring may cause overheating This air conditioning system meets strict safety and operating at connection points and a possible fire hazard.
Table of Contents Page 1. SPECIFICATIONS 1-1 Unit specifications 1-2 Major Component specifications 1-3 Other Component specifications 1-4 Noise Criterion Curves 12-13 2. DIMENSIONAL DATA 3. ELECTRICAL DATA 3-1 Electric Wiring Diagram 3-2 Control PCB switches and functions 4. FUNCTION 4-1 Room Temperature Control 4-2 Automatic control for heating and cooling 18-19...
1. SPECIFICATIONS 1-1 Unit Specifications SDAFM76-96-126R5I 220 - 240V ~ 50Hz Power source 230V Voltage rating Cooling Heating Performance See catalogue with the requested matching Capacity 470/380/340 Air circulation (High/Med./Low) m³/h Features Microprocessor/ I.C. thermostat Controls/Temperature controls K70D036Z / K70D042Z Remote Controller (Option) wired K70D040Z...
Page 5
SDAFM166-186R5I 220 - 240V ~ 50Hz Power source 230V Voltage rating Cooling Heating Performance See catalogue with the requested matching Capacity 620/540/450 Air circulation (High/Med./Low) m³/h Features Microprocessor/ I.C. thermostat Controls/Temperature controls K70D036Z / K70D042Z Remote Controller (Option) wired K70D040Z wireless 3 and Auto Fan speed...
Page 6
SDAFM226R5I 220 - 240V ~ 50Hz Power source 230V Voltage rating Cooling Heating Performance See catalogue with the requested matching Capacity 680/600/520 Air circulation (High/Med./Low) m³/h Features Microprocessor/ I.C. thermostat Controls/Temperature controls K70D036Z / K70D042Z Remote Controller (Option) wired K70D040Z wireless 3 and Auto Fan speed...
1-2 Major Component Specifications SDAFM76-96-126R5I Controller PCB CR-CRP50A-B Part No. Microprocessor Controls Fan & Fan Motor Type Centrifugal fan Q'ty ……. Dia. and lenght 2…. Ø 130 L 180 Fan motor model…Q'ty K35406-M02046 …1 4… 1040 No. Of poles…rpm (230 V, High) 0,17 Running Amps Power input...
Page 8
SDAFM166-186R5I Controller PCB CR-CRP50A-B Part No. Microprocessor Controls Fan & Fan Motor Type Centrifugal fan Q'ty ……. Dia. and lenght 2…. Ø 130 L 180 Fan motor model…Q'ty K48407-MO1596 …1 4… 1250 No. Of poles…rpm (230 V, High) 0,29 Running Amps Power input Ω...
Page 9
SDAFM226R5I Controller PCB CR-CRP50A-B Part No. Microprocessor Controls Fan & Fan Motor Type Centrifugal fan Q'ty ……. Dia. and lenght 2…. Ø 130 L 180 Fan motor model…Q'ty K48410-MO1598 …1 4… 1350 No. Of poles…rpm (230 V, High) 0,41 Running Amps Power input Ω...
1-4 Noise Criterion Curves MODEL: SDAFM76/96/126R5I MODEL: SDAFM166/186R5I SOUND LEVEL: HIGH SPEED SOUND LEVEL: HIGH SPEED CONDITION: IN FRONT OF THE UNIT 2m CONDITION: IN FRONT OF THE UNIT 2m frequency at center of sound pressure band (Hz) frequency at center of sound pressure band (Hz) MODEL: SDAFM226R5I SOUND LEVEL: HIGH SPEED CONDITION: IN FRONT OF THE UNIT 2m...
5. CONTROL OF THE AIR VOLUME TO THE OUTLET GRILLES The unit is prearranged to supply an external static pressure of about 7,5 Pa (7/9/12) and 10 Pa (16/18/22). Too high resistances in the air distribution system can cause an exceedingly small air volume to the outlet grilles. H= High fan speed M= Middle fan speed L= Low fan speed...
Page 19
H= High fan speed M= Middle fan speed L= Low fan speed SDAFM226R5I AIR FLOW VOLUME (m3/h)
6. REPLACING PCB 6-1 Replacing PCB About EEPROM (Erasable Programmable Read-Only Memory) EEPROM is a component in which the various information necessary for functionning can be electronically written or erased. This component holds informations that is essential for the running of the unit, and must be handled with care. D002 led lamp (red)
7. SERVICING AND MAINTENANCE FUNCTIONS 7-1. Indoor Unit Refrigerant Noise Countermeasures 7-2. Outdoor Unit Noise Countermeasure: EEPROM 05 (set at each outdoor unit)