Technibel SMDF95C5T Technical Data & Service Manual

Cool/fan functions with panel control. cool/dry/fan functions with remocon control.

Advertisement

Quick Links

TECHNICAL DATA & SERVICE MANUAL
7(&+1,%(/ 60')&7
7(&+1,%(/ 60')&7
7(&+1,%(/ 60')&7
)5(21 5$
&22/)$1 )81&7,216
:,7+ 3$1(/ &21752/
&22/'5<)$1 )81&7,216
:,7+ 5(02&21 &21752/
0.8180.481.0
JULY 2005

Advertisement

loading
Need help?

Need help?

Do you have a question about the TECHNIBEL SMDF95C5T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Technibel TECHNIBEL SMDF95C5T

  • Page 1 TECHNICAL DATA & SERVICE MANUAL )5(21 5$ 7(&+1,%(/ 60')&7 &22/)$1 )81&7,216 :,7+ 3$1(/ &21752/ 7(&+1,%(/ 60')&7 &22/'5<)$1 )81&7,216 7(&+1,%(/ 60')&7 :,7+ 5(02&21 &21752/ 0.8180.481.0 JULY 2005...
  • Page 2 7DEOH RI FRQWHQWV 3DJH 63(&,),&$7,216 1) Unit specifications 2) Major Component specifications 23(5$7,1* 5$1*( & ',0(16,21$/ '$7$ 5()5,*(5$17 )/2: ',$*5$06 3(5)250$1&( &+$576 5220 7(03(5$785( &21752/ +($7 (;&+$1*(5 )5267,1* 35(9(17,21 )81&7,216 1) Cool Mode Operation 2) Dry Mode Operation 3) Fan Mode Operation 4) Protection operations in Cool and Dry Mode 5) Sleep Function 6) Daily Timer Function...
  • Page 3: On The Unit

    63(&,),&$7,216  81,7 63(&,),&$7,216 81,7 02'(/ 60')&7 60')&7 60')&7 Power source 230 V 50 Hz 3(5)250$1&(6 &22/,1* &22/,1* &22/,1* Capacity (air 9042 BTU / h 9930 13680 conditioner) 2,65 2,91 4,01 420/300 Air circulation (high/med/low) 420/300 460/350 Moisture removal (high speed) Cooling l / h 27°C ( 60% R.U.) liters / 24h...
  • Page 4  0$-25 &20321(17 63(&,),&$7,216 81,7 02'(/ 60')&7 60')&7 60')&7 &21752//(5 3&% Part No. KSA - CTRL - DB Controls Microprocessor Control circuit fuse (F1) 250VAC - 5A -T 2,54mm - 6 pcs Jumper Setting J1….J8 5(027( &21752/ 81,7 PANEL CONTROL REMOCON RC-7 (ST) 7+(50,6725 &2,/ 6(1625 7+ NTC (with brass pipe)
  • Page 5 81,7 02'(/ 60')&7 60')&7 60')&7 &21'(16$7( 3803 3& Model PC 95643 Rating 230 V 50 Hz Nominal input 12 ± 10% Coil resistance (at 20° C) 122 ± 10% 6$)(7< )/2$7 6:,7&+ 06 25 )6 F83161,3 Model Contact rating 10(4)A - 250VAC OPEN FLOAT CLOSE...
  • Page 6 & ',0(16,21$/ '$7$ 60')&7 60')&7 60')&7 5()5,*(5$17 )/2: ',$*5$0 &22/,1* 02'(/...
  • Page 7 3(5)250$1&( &+$576 23(5$7,1* &+$5$&7(5,67,&6 :,7+ 5(/$7,9( +80,',7< $5281'  60')&7 32 °C 27 °C 21 °C EXTERNAL TEMPERATURE (°C) 60')&7 21 °C 27 °C 32 °C EXTERNAL TEMPERATURE (°C) 60')&7 21 °C 27 °C 32 °C EXTERNAL TEMPERATURE (°C)
  • Page 8 5220 7(03(5$785( &21752/ 21/< 60')&7 Room temperature control is obtained by cycling the compressor ON and OFF by means of room temperature sensor TH minimum 2 minutes ON/OFF SWITCH COMPRESSOR SWITCH COMPRESSOR TEMPERATURE +1°C TEMPERATURE 6(7 63((' 127(6 1. If the compressor is turned off, the control circuit sets an automatic minimum 3 minutes delay to protect the compressor from stalling out when trying to start against the high side refrigerant pressure.
  • Page 9 )81&7,21 21/< 60')&7 60')&7  &RRO 0RGH 2SHUDWLRQ...
  • Page 10  'U\ 0RGH 2SHUDWLRQ...
  • Page 11  )DQ 0RGH 2SHUDWLRQ  3URWHFWLRQ RSHUDWLRQV LQ &RRO DQG 'U\ 0RGH  3URWHFWLRQ 2SHUDWLRQV LQ &RRO DQG 'U\ 0RGHV...
  • Page 12  6OHHS )XQFWLRQ  'DLO\ 7LPHU )XQFWLRQ  ,)((/ )XQFWLRQ...
  • Page 13  2XWGRRU &RLO +LJK 3UHVVXUH 3URWHFWLRQ...
  • Page 14 (/(&75,& :,5,1* ',$*5$06 60')&7 60')&7 60')&7 Indicator 3&%  &( Controller 6:,1'$66< assy TIMER )0,  )0 Indoor fan motor 7+ Thermistor POWER RELAY Power transformer Terminal plate &0 +:& Compressor motor Hot water control 2/5 Overload relay Limit water thermostat Outdoor fan motor Water electric valve &...
  • Page 15 7528%/(6+227,1*...
  • Page 16 (Operation lamp is blinking) The condensate drain system is obstructed...
  • Page 19 Unit still does Unit still does not run not run...
  • Page 20 Only if IFEEL is selected Temperature difference between suction and discharge Temperature difference between susction and discharge air is large enough (approx. 15°C or more) air too big (approx. 15 °c or more) install an additional unit 21/< 02'(/6 60')&760')&7 Only if IFEEL is selected...
  • Page 22 &+(&.,1* (/(&75,&$/ &20321(176...
  • Page 24 R.D. 28 Reyrieux BP 131 - 01601 Trévoux CEDEX France Tél. 04.74.00.92.92 - Fax 04.74.00.42.00 R.C.S. Bourg-en-Bresse B 759 200 728...

This manual is also suitable for:

Technibel smdf145c5tTechnibel smdf115c5t