Technibel SPA250R5TAA Technical & Service Manual page 24

Table of Contents

Advertisement

1. SPECIFICATIONS
Indoor Unit : SPA360R5TAA
RATING CAPACITY : 10.6 kW
EVAPORATOR
ENT. TEMP. °C
WB
DB
21
23
15
25
27
29
31
21
23
17
25
27
29
31
21
23
19
25
27
29
31
23
21
25
27
29
31
23
25
27
29
31
25
27
29
31
TC
: Total Cooling Capacity
SHC : Sensible Heat Capacity
CI
: Compressor Input
Rating conditions (#MARK) : Outdoor Ambient Temperature
Outdoor Unit : GR360R7TAA
AIR FLOW RATE : 1680 m
CONDENSER
AMBIENT TEMP.
25
TC
10.7
CI
2.15
SHC
7.2
SHC
8.2
SHC
9.1
SHC
10
SHC
10.7
SHC
10.7
TC
11.06
CI
2.2
SHC
6.1
SHC
7
SHC
8
SHC
8.9
SHC
9.8
SHC
10.7
TC
11.45
CI
2.27
SHC
5
SHC
5.9
SHC
6.8
SHC
7.7
SHC
8.7
SHC
9.6
TC
11.82
CI
2.33
SHC
4.8
SHC
5.7
SHC
6.6
SHC
7.5
SHC
8.4
TC
12.22
CI
2.4
SHC
4.6
SHC
5.5
SHC
6.4
SHC
7.3
TC
12.72
CI
2.47
SHC
4.4
SHC
5.3
SHC
6.2
(kW)
(kW)
(kW)
Indoor Unit Entering Air Temperature 27°C DB / 19°C WB
– 24 –
3
/h
°C
30
35
10.21
9.69
2.29
2.46
7
6.7
7.9
7.7
8.8
8.6
9.7
9.5
10.21
9.69
10.21
9.69
10.61
10.11
2.36
2.53
5.9
5.7
6.8
6.6
7.7
7.5
8.7
8.4
9.6
9.3
10.5
10.11
11.03
#10.6
2.43
2.61
4.8
4.6
5.7
5.5
6.6
6.5
7.6
7.4
8.5
8.3
9.4
9.2
11.41
10.97
2.5
2.68
4.6
4.4
5.5
5.4
6.4
6.3
7.4
7.2
8.3
8.1
11.86
11.45
2.57
2.75
4.4
4.3
5.3
5.2
6.3
6.1
7.2
7
12.27
11.9
2.65
2.81
4.2
4.1
5.1
5
6
5.9
35°C DB
40
45
9.08
8.44
2.63
2.82
6.4
6.1
7.4
7
8.3
8
9.08
8.44
9.08
8.44
9.08
8.44
9.57
8.98
2.71
2.89
5.4
5.2
6.4
6.1
7.3
7
8.2
7.9
9.1
8.8
9.57
8.98
10.07
9.5
2.79
2.97
4.4
4.2
5.3
5.1
6.2
6
7.2
6.9
8.1
7.8
9
8.7
10.47
9.96
2.87
3.06
4.2
4
5.2
5
6.1
5.9
7
6.8
7.9
7.7
11.02
10.52
2.95
3.14
4.1
3.9
5
4.9
5.9
5.8
6.9
6.7
11.49
11.05
3.02
3.23
4
3.8
4.9
4.7
5.8
5.6

Advertisement

Table of Contents
loading

Table of Contents