  • Page 1 GB751V INSTALLATION TOOL GAGE BILT TOOLS ARE AVAILABLE WORLDWIDE E-MAIL US FOR A DISTRIBUTOR NEAR YOU. GAGE BILT Inc. GAGE BILT 44766 Centre Court (586) 226-1500 Clinton Twp. MI 48038 (586) 226-1505 Fax MADE IN U.S.A. e-mail: solutions@gagebilt.com / www.gagebilt.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Description Page Warnings ..................................... 3 Principle of Operation ................................4 How to use the GB751V ................................5 Description and Maintenance ..............................6 Filling, Bleeding ..................................7 Troubleshooting ..................................8 Overhaul ..................................... 9 Disassembly and Parts Lists.............................. 10-11 DEXRON®...
  • Page 3: Warnings

    73.2 dB (A). In this for damage or wear. Any repair should be done by condition the max level was 81.5 dB (A). Therefore, qualified personnel trained on Gage Bilt it is required where prolonged use, hearing procedures.
  • Page 4: Principle Of Operation

    PRINCIPLE OF OPERATION When the actuator lever assy is depressed, the pressurized air inside of the tool is released allowing spring pressure to move the valve spool assy causing the air to be redirected. The air is directed to the top of the air piston assy, moving it in a downward direction.
  • Page 5: How To Use The Gb751V

    HOW TO USE THE GB751V WARNING: Operator MUST read and understand all warnings and cautions. WARNING: It is required that eye protection and hearing protection be worn during operation. WARNING: Do not pull rivet in the air. Personal injury from fastener ejecting may occur.
  • Page 6: Description And Maintenance

    2200 lbs. (9.8 kN) with 90 psi. (6.2 bar) air pressure at the air inlet. The GB751V riveter operates on a wide range of air pressure, with 90 to 100 psi. (6.2-6.9 bar) providing the maximum efficiency. At 90 psi. (6.2 bar) air pressure, the GB751V does not exceed 81.5 dB (A) and consumes 3 cfm at 20 cycles a minute.
  • Page 7: Filling, Bleeding

    FILLING AND BLEEDING TOOL NOTE: Air bleeder assy (704153) is required. WARNING: Do not cycle tool without air bleeder assy (704153), or the button head cap screw (402482) and stat-o-seal (S572), installed in the head cylinder assy (703109). Severe personal injury may result. CAUTION: Before filling handle assy (704132), the air piston assy (704121) should be all the way down.
  • Page 8: Troubleshooting

    TROUBLESHOOTING Providing all maintenance conditions have been met, follow this systematic approach to diagnosis. 1. MORE THAN ONE PULL IS REQUIRED TO BREAK RIVET. a) Tool needs to be bled. (See filling and bleeding instructions.) b) Spring has fatigued, replace. c) Jaws are stripped or packed with chips.
  • Page 9: Overhaul

    WARNING: Tool must be maintained in a safe working condition at all times and examined on a daily basis for damage or wear. Any repair should be done by qualified personnel trained on Gage Bilt procedures. WARNING: When operating, repairing or overhauling tool, wear approved eye protection. Do not look in front of tool or rear of tool when installing fastener.
  • Page 10: Disassembly And Parts Lists

    HEAD WARNING: Dispose of hydraulic oil in accordance with all environmental regulations applicable in your area. Remove nose assembly and adapter from tool before attempting disassembly of head assy. Remove end cap (703114-1). Push against threaded end of piston (751307) to slide it out of head cylinder assy (703109). Be careful not to damage threads or cause burrs on polished piston (751307) surface.
  • Page 11 HANDLE To inspect air cylinder bore, remove base cover (704125). Any further disassembly will require removal of the head cylinder assy (703109) first. For complete disassembly, start by removing base cover (704125). Next, holding tool upright, remove four button-head cap screws (A-928). Lift head cylinder assy (703109) from handle assy (704132) and set aside o'ring (S832) and gasket (704129). Empty all hydraulic oil into an approved container and dispose of in accordance with all environmental regulations applicable in your area.
  • Page 12: Dexron® Iii Oil Safety Data

    DEXRON® III OIL SAFETY DATA FIRST AID MEASURES Eye: No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water. Skin: No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated. To remove the material from skin, use soap and water.
  • Page 13: Nose Assembly Selection Chart

    ASP® IS A REGISTERED TRADEM ARK OF ALCOA INC. CHERRYM AX® AND M BC® ARE REGISTERED TRADEM ARKS OF CHERRY AEROSPACE. FASTACK® AND SUPERTACK® ARE REGISTERED TRADEM ARKS OF ALLFAST FASTENING SYSTEM S INC. GAGE BILT CERTIFIES THE GB751 WILL INSTALL THE ABOVE FASTENERS PLEASE NOTE: Due to lever assembly 1) RIGHT ANGLE NOSE ASSEMBLIES MAY REQUIRE MORE THAN ONE PULL.
  • Page 14: Warranty

    WARRANTY Seller warrants that all goods covered by this catalog will conform to applicable specifications and will replace or repair, F.O.B. our plant, any goods providing defective from faulty workmanship, or material, for 6 months from date of shipment Said warranty to remain in effect if, and only if, such goods are used in accordance with all instructions as to maintenance, operation and use, set forth in manuals and instruction sheets furnished by seller.