GB752SR INSTALLATION TOOL GAGE BILT TOOLS ARE AVAILABLE WORLDWIDE E-MAIL US FOR A DISTRIBUTOR NEAR YOU. GAGE BILT Inc. GAGE BILT 44766 Centre Court (586) 226-1500 Clinton Twp. MI 48038 (586) 226-1505 Fax MADE IN U.S.A. e-mail:solutions@gagebilt.com / www.gagebilt.com...
Description Page Warnings ............................... 3 Principle of Operation ......................4 How to use the GB752SR ........................5 Description, Maintenance and Hydraulic Thread Preparation ............6 Filling and Bleeding ..........................7 Troubleshooting ........................... 8 Overhaul, Disassembly and Parts Lists ..................9-10 DEXRON®...
81.5 dB (A). Therefore, daily basis for damage or wear. Any repair should it is required where prolonged use, hearing be done by qualified personnel trained on Gage Bilt protection be used. procedures. WARNING...
PRINCIPLE OF OPERATION When the lever ass’y is depressed, the pressurized air inside of the tool is released allowing spring pressure to move the valve spool causing the air to be redirected. The air is directed to the top of the air piston ass’y, moving it in a downward direction.
HOW TO USE THE GB752SR WARNING: OPERATOR MUST READ AND UNDERSTAND ALL WARNINGS AND CAUTIONS. WARNING: IT IS REQUIRED THAT EYE PROTECTION AND HEARING PROTECTION BE WORN DURING OPERATION. WARNING: DO NOT PULL RIVET IN THE AIR. PERSONAL INJURY FROM FASTENER EJECTING MAY OCCUR.
3 cfm at 20 cycles per minute. The GB752SR comes with 3 feet of hose. Hoses can be attached in the top rear or the bottom of the split handle depending on the application. Vacuum systems are available for this tool, please consult our engineering department for specific applications.
FILLING & BLEEDING PROCEDURE: NOTE: 704153 and 745163 air bleeder ass’y & fill bottle ass’y are required. NOTE: To replace a small amount of fluid follow bleeding steps 5-6 . IMPORTANT: Be sure to use thread sealant on all hydraulic fittings, Loctite® 30534 or similar Teflon® infused pipe dope is recommended.
TROUBLE SHOOTING Providing all maintenance conditions have been met, follow this systematic approach to diagnosis. 1. MORE THAN ONE PULL IS REQUIRED TO BREAK RIVET. a) Tool needs to be bled. (See filling and bleeding instructions.) b) Spring has fatigued, replace. c) Jaws are stripped or packed with chips.
HEAD Remove nose assembly from tool before attempting disassembly of head assembly. Remove end cap (752313). Push against threaded end of piston (752507) to slide it out of head cylinder ass’y (752124). Be careful not to damage threads or cause burrs on polished piston rod ass’y surface. WARNING: DISPOSE OF HYDRAULIC FLUID IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REGULATIONS.
Page 10
HANDLE To inspect air cylinder bore, remove base cover (704125). Any further disassembly will require removal of the manifold-handle (744303) first. For complete disassembly, start by removing base cover (704125). Next, holding tool upright, remove four socket- head cap screws (A-928). Lift manifold-handle (744303) from handle (704132) and set aside o'ring (S832) and gasket (704129). Emp- ty all hydraulic fluid into an approved container and dispose of in accordance with all environmental laws and regulations applicable in your area.
DEXRON® III OIL SAFETY DATA FIRST AID MEASURES Eye: No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water. Skin: No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated. To remove the material from skin, use soap and water.
4) BACS53B -10 ONLY NOTE: THE LAST 2 DIGITS OF THE NOSE ASSEMBLY REPRESENTS THE LENGTH THE NOSE EXTENDS FROM THE TOOL I.E. -20 = 2.0 INCHES GB752SR MODELS MUST USE -45 LENGTH OR LONGER ON ALL 752 STYLE NOSES 11/14...
GAGE BILT DECLARATION OF CONFORMITY MANUFACTURER: Gage Bilt Inc. 44766 Centre Ct. Clinton Twp. Michigan (586-226-1500) WE DECLARE THAT THE EQUIPMENT SPECIFIED HEREIN CONFORMS TO THE FOLLOWING DIRECTIVES AND STANDARDS Machinery Directive 2006/42/EC EN12100-1 & EN12100-2 EN792-1:2000+A1 EU REPRESENTATIVE Edgar Hausmann GmbH Förster-Busch-Str. 10 D-34346 Hann. Münden Germany EQUIPMENT DESCRIPTION: GB752SR FASTENER INSTALLATION TOOL This product specified above conforms to the above dIrectives and standards.