  • Page 1 GB752SH INSTALLATION TOOL GAGE BILT TOOLS ARE AVAILABLE WORLDWIDE E-MAIL US FOR A DISTRIBUTOR NEAR YOU. GAGE BILT Inc. GAGE BILT 44766 Centre Court (586) 226-1500 Clinton Twp. MI 48038 (586) 226-1505 Fax MADE IN U.S.A. e-mail:solutions@gagebilt.com / www.gagebilt.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Description Page Warnings ..................................... 3 Principle of Operation and How to use the GB752SH......................4 Description, Maintenance and Hydraulic Thread Preparation ....................5 Filling and Bleeding .................................. 6 Troubleshooting ..................................7 Overhaul, Disassembly and Parts Lists ..........................8-10 DEXRON ®...
  • Page 3: Warnings

    73.2 dB (A). In this for damage or wear. Any repair should be done by condition the max level was 81.5 dB (A). Therefore, qualified personnel trained on Gage Bilt it is required where prolonged use, hearing procedures.
  • Page 4: Principle Of Operation And How To Use The Gb752Sh

    Air pressure is then built up inside of the handle assy causing the valve spool assy to return to its original position and reversing the sequence directing air pressure to the rear of the head cylinder assy, causing the piston to move to the forward position. HOW TO USE THE GB752SH WARNING: Operator MUST read and understand all warnings and cautions.
  • Page 5: Description, Maintenance And Hydraulic Thread Preparation

    The GB752SH split handle riveter operates on a wide range of air pressure, with 90 to 100 psi. (6.2-6.9 bar) providing maximum efficiency. At 90 psi. (6.2 bar) air pressure, the GB752SH does not exceed 81.5 dB (A) and consumes 3 cfm at 20 cycles per minute.
  • Page 6: Filling And Bleeding

    FILLING & BLEEDING PROCEDURE: NOTE: Air bleeder assy (704153) and fill bottle (745263) are required. WARNING: Do not cycle tool without air bleeder assy, or button head cap screw and stat-o-seal, installed in tool head. Severe personal injury may result. CAUTION: Before filling handle, air piston assy should be all the way down.
  • Page 7: Troubleshooting

    TROUBLESHOOTING Providing all maintenance conditions have been met, follow this systematic approach to diagnosis. 1. MORE THAN ONE PULL IS REQUIRED TO BREAK RIVET. a) Tool needs to be bled. (See filling and bleeding instructions.) b) Spring has fatigued, replace. c) Jaws are stripped or packed with chips.
  • Page 8: Overhaul, Disassembly And Parts Lists

    WARNING: Tool must be maintained in a safe working condition at all times and examined on a daily basis for damage or wear. Any repair should be done by qualified personnel trained on Gage Bilt procedures. WARNING: When operating, repairing or overhauling tool, wear approved eye protection. Do not look in front of tool or rear of tool when installing fastener.
  • Page 9 HEAD WARNING: Dispose of hydraulic oil in accordance with all environmental regulations applicable in your area. Remove nose assembly from tool before attempting disassembly of head assembly. Remove end cap (752313). Push against threaded end of piston (752507) to slide it out of head cylinder assy (752120). Be careful not to damage threads or cause burrs on polished piston rod assy surface.
  • Page 10 HANDLE To inspect air cylinder bore, remove base cover (744124). Any further disassembly will require removal of the manifold-handle (744303) first. For complete disassembly, start by removing base cover (744124). Next, holding tool upright, remove four button-head cap screws (400062). Lift manifold-handle (744303) from handle assy (744129) and set aside o'ring (S832) and gasket (704129). Empty all hydraulic oil into an approved container and dispose of in accordance with all environmental laws and regulations applicable in your area.
  • Page 11: Dexron® Iii Oil Safety Data

    DEXRON® III OIL SAFETY DATA FIRST AID MEASURES Eye: No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water. Skin: No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated. To remove the material from skin, use soap and water.
  • Page 12: Nose Assembly Selection Chart

    TRADEM ARKS OF AVDEL UK LIM ITED. ASP®, M AGNA-LOK® AND M AGNA-BULB® ARE REGISTERED TRADEM ARKS OF ALCOA INC. BULB-TITE® IS A REGISTERED TRADEM ARK OF GESIPA FASTENERS USA, INC. ULTRA-GRIP® IS A REGISTERED TRADEM ARK OF EM HART TEKNOLOGIES. GAGE BILT CERTIFIES THE GB752 WILL INSTALL THE ABOVE FASTENERS PLEASE NOTE: Due to *ALL RIGHT ANGLE NOSES REQUIRE 752142 STROKE LIMITER.
  • Page 13: Eu Conformity And Warranty

    GAGE BILT DECLARATION OF CONFORMITY MANUFACTURER: Gage Bilt Inc. 44766 Centre Ct. Clinton Twp. Michigan (586-226-1500) WE DECLARE THAT THE EQUIPMENT SPECIFIED HEREIN CONFORMS TO THE FOLLOWING DIRECTIVES AND STANDARDS Machinery Directive 2006/42/EC EN12100-1 & EN12100-2 EN792-1:2000+A1 EU REPRESENTATIVE Edgar Hausmann GmbH Förster-Busch-Str. 10 D-34346 Hann. Münden Germany EQUIPMENT DESCRIPTION: GB752SH FASTENER INSTALLATION TOOL This product specified above conforms to the above dIrectives and standards.