Summary of Contents for Crane PROSSER 4SED-L Series
Page 1
Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur. As such Crane Pumps & Systems reserves the right to change product without prior written notifi cation.
PRESSURE GAUGE KIT (see parts list) Other brand and product names are trademarks or registered trademarks of their respective holders. ® PROSSER is a registered trademark of Crane Pumps & Systems, Inc 1996, 2002, 8/2004 , 2/06, 9/06 Alteration Rights Reserved...
WARNING! - DO NOT pump hazardous materials IMPORTANT! - Crane Pumps & Systems, Inc. is not (fl ammable, caustic, etc.) unless the pump is specifi cally responsible for losses, injury, or death resulting from a designed and designated to handle them.
For the location of the nearest Prosser Service Center, check straight as possible as excessively bent hose reduces water your Prosser representative or Crane Pumps & Systems, Inc., quantity. Refrain from placing the end of discharge hose Service Department in Piqua, Ohio, telephone (937) 778-8947 under water or reverse siphioning may occur when pump is or Crane Pumps &...
C-3.2) Overload Protection : TEMPERATURE SENSOR ELECTRICAL RATINGS Volts Continuous Inrush C-3.2-1) Three Phase - The normally closed (N/C) thermal Amperes Amperes sensor is embedded in the motor windings and will detect 110-120 3.00 30.0 excessive heat in the event an overload condition occurs. The thermal sensor will trip when the windings become too hot 220-240 1.50...
As the motor is oil fi lled, no lubrication or other maintenance cooling oil as per Table 1. An air space must remain in the top is required, and generally Crane Pumps & Systems will give of the motor housing to compensate for oil expansion (see very reliable service and can be expected to operate for years Fig.
Page 8
If found to be defective Seal Chamber - Remove pipe plug (22) from Bearing Bracket contact a motor service station or Crane Pumps & Systems (21) and check that seal chamber is full of oil. Apply pipe service department.
Page 9
FIGURE 3 Motor - Slide lower bearing (47) and motor rotor squarely into F-4) Shaft Seal and Diaphragm Service: the bearing bracket (21) until bearing seats on the bottom. Important! - Handle seal parts with extreme care. Position motor housing and stator into pilot, install bellville do not scratch or mar lapped surfaces.
Page 10
Seal - To expose shaft seal (46) for examination, complete Make sure driving lugs in retainer are matched in rotating above procedure and slide off outboard rotating member member. Place spring (46C) over shaft and in place on rotating (46B), See Figure 4. Remove inboard rotating member (46), member (46E), making sure it is seated in retainer and not from shaft.
Page 11
SINGLE PHASE 240 VOLT AC SINGLE PHASE 240 VOLT AC THREE PHASE 480-600 VOLT AC THREE PHASE 480-600 VOLT AC Power Cable Power Cable Motor Lead Number Motor Lead Number Power Cable Power Cable Motor Lead Number Motor Lead Number Green (Ground) Green Green (Ground)
SECTION: G REPLACEMENT PARTS G-1 ORDERING REPLACEMENT PARTS: When ordering replacement parts, ALWAYS furnish the following information: 1. Pump serial number and date code. (Paragraph G-4) 2. Pump model number. (Paragraph G-3) 3. Pump part number. (Paragraph G-2) 4. Part description. 5.
TROUBLE SHOOTING CAUTION ! Always disconnect the pump from the electrical power source before handling. If the system fails to operate properly, carefully read instructions and perform maintenance recommendations. If operating problems persist, the following chart may be of assistance in identifying and correcting them: MATCH “CAUSE”...
Page 18
Limited 24 Month Warranty Crane Pumps & Systems warrants that products of our manufacture will be free of defects in material and workmanship under normal use and service for twenty-four (24) months after manufacture date, when installed and maintained in accordance with our instructions.This warranty gives you specifi c legal rights, and there may also be other rights which vary from state to state.
Crane Pumps & Systems, Inc. Distributor. RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZATION”. CONTACT YOUR LOCAL CRANE PUMPS & SYSTEMS, INC. DISTRIBUTOR. Products Returned Must Be Cleaned, Sanitized, Or Decontaminated As Necessary Prior To Shipment, To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material.
Page 20
This form is designed to provide assurance that customer service and a quality product are the number one priority with Crane Pumps & Systems, Inc (CP&S). Please fi ll out the following questions as completely and accurate as possible. When complete, mail this form to: In U.S.A Send To:...
Page 21
CP&S control panel part no. and brand Number of pumps operated by control panel NOTE: At no time should holes be made in top of control panel, unless proper sealing devices are utilized. Control panel manufactured by others Company name Model number Short circuit protection Type...
Need help?
Do you have a question about the PROSSER 4SED-L Series and is the answer not in the manual?
Questions and answers