Summary of Contents for Lantech IPES-5208T-X Series
Page 1
IPES-5208T-X, IPES-5208T IPES/IES-5208DF Series 8 10/100TX D-coded + 2 10/100/1000T (X-coded) or 2 100/1000 FX (w/8 PoE at/af) Industrial Managed Switch w/Enhanced G.8032 Ring User Manual (Hardware) Sept. 2017...
Page 2
Recommendation for Shielded network cables STP cables have additional shielding material that is used to reduce external interference. The shield also reduces the emission at any point in the path of the cable. Our recommendation is to deploy an STP network cable in demanding electrical environments. Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable.
Page 3
Lantech Communications Global Inc. Products offered may contain software which is proprietary to Lantech Communications Global Inc. The offer or supply of these products and services does not include or infer any transfer of ownership.
Page 4
FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy.
Page 7
148,800pps for Fast Ethernet port 1,488,000pps for Gigabit Fiber Ethernet port Marvell 800Mhz 256M Byte Flash 128M Byte Mac Address 16K MAC address table Jumbo frame 10KB on all ports Connectors 10/100TX: 8 x ports M12 4-pole X-coded with Auto MDI/MDI-X function 10/100/1000T: 4 x ports M12 8-pole A-coded with Auto MDI/MDI- X function...
Page 8
Storage -40°C~85°C / -40°F~185°F Temperature Power Supply 9.5~56VDC on 12V model 50.4~90VDC on 72V model 43~137.5VDC on 110V model with input isolation PoE Budget 80W for 12V input 120W for 24V input 80W for 72V Input 80W for 110V Input PoE pin M12 port # 1~#8 support IEEE 802.3at/af End-point, Alternative A assignment...
Page 9
*Future release **Optional IPES-5208T-43 Standards IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX IEEE802.3z Gigabit fiber IEEE802.3x Flow Control and Back Pressure IEEE802.3ad Port trunk with LACP IEEE802.1d Spanning Tree IEEE802.1w Rapid Spanning Tree IEEE802.1s Multiple Spanning Tree IEEE 802.3ad Link Aggregation Control Protocol (LACP) IEEE 802.1AB Link Layer Discovery Protocol (LLDP) IEEE 802.1X User Authentication (Radius) IEEE802.1p Class of Service...
Page 11
Power Max. 13W 12V~48VDC input Consumption Max. 16W 72/110VDC input Case IP43 model: Aluminum case Dimension 203mm(W)x187mm(H)x84.4mm(D) Weight 1.0kgs Installation DIN Rail** and Wall Mount Design EMI & EMS FCC Class A, CE EN55022 Class A, CE EN55024, CE EN61000-4-2, CE EN61000-4-3, CE EN61000-4-4, CE EN61000-4-5, CE EN61000- 4-6, CE N61000-4-8, EN61000-4-11 Stability Testing...
Page 12
IEEE802.1Q VLAN Tag IEEE802.3at/af Power over Ethernet Switch Back-plane (Switching Fabric): 5.6Gbps Architecture Packet throughput ability (Full-Duplex): 23.8Mpps @64bytes Transfer Rate 14,880pps for Ethernet port 148,800pps for Fast Ethernet port 1,488,000pps for Gigabit Fiber Ethernet port Marvell 800Mhz 256M Byte Flash 128M Byte Mac Address...
Page 14
IP43 model: Aluminum case 203mm(W)x187mm(H)x84.4mm(D) Weight 1.4kgs (IP67); 1.2kgs(IP43) Installation DIN Rail** and Wall Mount Design EMI & EMS FCC Class A, CE EN55022 Class A, CE EN55024, CE EN61000-4-2, CE EN61000-4-3, CE EN61000-4-4, CE EN61000-4-5, CE EN61000- 4-6, CE N61000-4-8, EN61000-4-11 Stability Testing IEC60068-2-32 (Free fall), EN61373 (Shock and Vibration) MTBF...
Page 15
Transfer Rate 14,880pps for Ethernet port 148,800pps for Fast Ethernet port 1,488,000pps for Gigabit Fiber Ethernet port Marvell 800Mhz 256M Byte Flash 128M Byte Mac Address 16K MAC address table Jumbo frame 10KB on all ports Connectors 10/100TX: 8 x ports M12 4-pole D-coded with Auto MDI/MDI-X function 100/1000 Dual Speed Fiber: 2 x LC connector for single-mode or multi-mode type fiber cable...
Page 16
DI/DO 1 Digital Input (DI) : Level 0: -30~2V / Level 1: 10~30V Max. input current:8mA 1 Digital Output(DO): Open collector to 40 VDC, 200mA Operating 5% ~ 95% (Non-condensing) Humidity Operating -40°C~75°C / -40°F~167°F Temperature (72V model: -40°C~60°C / -40°F~140°F) Storage -40°C~85°C / -40°F~185°F Temperature...
2.2 Package Content: Manual CD Product Console cable 2.3 IP Protection The IP Code, Ingress Protection Rating, sometimes also interpreted as International Protection Rating, classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water in mechanical casings and with electrical enclosures.
Page 24
Any large surface of the body, such as the back of a >50 mm hand, but no protection against deliberate contact with a body part >12.5 mm Fingers or similar objects >2.5 mm Tools, thick wires, etc. >1 mm Most wires, screws, etc. Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the Dust protected...
Page 25
Spraying Water falling as a spray at Test duration: 5 minutes water any angle up to 60° from Water volume: 0.7 litres per the vertical shall have no minute harmful effect. Pressure: 80–100 kPa Splashing Water splashing against Test duration: 5 minutes of water the enclosure from any Water volume: 10 litres per...
the manufacturer. Normally, this will mean that the equipment is hermetically sealed. However, with certain types of equipment, it can mean that water can enter but only in such a manner that it produces no harmful effects. — Powerful Protected against close- high range high pressure, high temperature...
Page 27
No failure A network device is detected. The port is transmitting or receiving packets Link/Ack Blinking from the TX device. P1 ~ P8 No device attached The port is operating in PoE mode.(IPES) PoE(1~8)(IP The port is not operating in PoE mode.(IPES) A network device is detected.
Chapter 3 Hardware Installation 3.1Hardware installation 3.1.1Unpack switch and check the accessory with packing content list 3.1.2 Mount the switch on desired position. For the best ventilation, it is suggested to mount the switch on metallic surface. 3.1.3 Connect the M23/M12 connector of power input. The PoE power supply for IPES-5208T-X/ IPES-5208T/ IPES-5208DF is connected via a 5- pole M23 female connector while IES-5208DF is with a 5-pole M12 female connector.
Page 29
9.5V to 56VDC to feed power on both the 802.3af and 802.3at standardized devices. 72V model: The power input voltage can be from 50.4V to 90VDC to feed power on both 802.3af/at standardized devices. 110V model: The power input voltage can be from 43V to 137.5VDC to feed power on both 802.3af/at standardized devices.
Page 30
Dual Power Input The power input can be supported redundantly. The supply voltage is electrically isolated from the housing. Note: With single power supply of the mains voltage, the device will report a power failure. You can disable this power fail event via web browser.
Page 31
Ground screw 3.1.5 Connect the M12 connector with RJ-45 data cable, ports are not used shall be caped that comes with the package to insulate the surrounding.
Page 32
Pin assignment of M12 10/100Tx network connector Pin assignment of M12 10/100/1000T network connector...
Page 33
3.1.6 Check the status of LED, make sure the switch was in working status. Note: The protection class IP67 is only achieved when bolted together. The other components attaching to the system have to meet with the IP67 protection class in order to reach the whole system IP67 protection. ...
Chapter 4 Network Application 4.1 ITU G.8032 Scheme LANTECH G.8032 protocol is following ITU (International Telecommunication Unit) G.8032 v2 draft. The benefits of G.8032 are: 1. <50ms recovery time when failover 2. G.8032 has defined the protocol scheme, parameters, functions, test measures to be unified that the users can evaluate the possible network infrastructure without literally testing each brand in large scale.
Chapter 5 Console Management 5.1 Connecting to the Console Port The supplied cable which one end is M12 5-pole connector and the other end is RS-232 connector. Attach the end of RS-232 connector to PC or terminal and the other end of M12 connector to the console port of the switch.
Page 39
The settings of communication parameters Having finished the parameter settings, click ‘OK’. When the blank screen shows up, press Enter key to have the login prompt appears. Key in ‘admin’ (default value) for both User name and Password (use Enter key to switch), then press Enter and the Main Menu of console management appears.