Lantech IPES/IES-5416T Series User Manual

Lantech IPES/IES-5416T Series User Manual

16 10/100tx + 4 1000t l2+ (w/8 or 16 poe at/af) en50155 managed ethernet switch

Advertisement

IPES/IES-5416T Series
+
16 10/100TX + 4 1000T L2
(w/8 or 16 PoE at/af)
EN50155 Managed Ethernet Switch
User Manual (Hardware)
IP-67
IP-54
IP-43
NOV. 2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IPES/IES-5416T Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lantech IPES/IES-5416T Series

  • Page 1 IPES/IES-5416T Series 16 10/100TX + 4 1000T L2 (w/8 or 16 PoE at/af) EN50155 Managed Ethernet Switch User Manual (Hardware) IP-67 IP-54 IP-43 NOV. 2019...
  • Page 2 Recommendation for Shielded network cables STP cables have additional shielding material that is used to reduce external interference. The shield also reduces the emission at any point in the path of the cable. Our recommendation is to deploy an STP network cable in demanding electrical environments. Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable.
  • Page 3 Lantech Communications Global Inc. Products offered may contain software which is proprietary to Lantech Communications Global Inc. The offer or supply of these products and services does not include or infer any transfer of ownership.
  • Page 4 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy.
  • Page 5: Table Of Contents

    Content Chapter 1 Introduction ........... 5 Chapter 2 Hardware Description......6 Physical Dimension ........6 Package Content: ......... 8 IP Protection ..........9 LED Indicators ..........12 Chapter 3 Hardware Installation ......14 Chapter 4 Network Application ......21 4.1 ITU G.8032 Scheme........21 4.2 Ring Coupling ..........21 4.3 Multiple Rings ..........22 4.4 Dual Homing ..........23...
  • Page 6: Chapter 1 Introduction

    Chapter 1 Introduction Lantech IES-5416T & IPES-5416T-8/16 (IP67/IP54/IP43) series is a high performance IP67/IP54/IP43 industrial Gigabit uplink switch with 8x10/100TX + 2 GigaT + 2Dual Speed Giga FX (w/8 or 16 PoE at/af injectors: IPES models) by M12 connectors which...
  • Page 7: Chapter 2 Hardware Description

    Chapter 2 Hardware Description In this paragraph, it will describe the Industrial switch’s hardware spec, port, cabling information, and wiring installation. 2.1 Physical Dimension Aluminum case. IP-67, 285 (W) x 201.4 (D) x 84.4 (H) mm Port description of IP-67 series switch...
  • Page 8 Aluminum case. IP-54, 252mm(W)x179.5mm(H)x76.5mm(D) Aluminum case. IP-43, 273 (W) x 188.4(D) x 84.4 (H) mm...
  • Page 9: Package Content

    **The port description of IP-54/IP-43 model is the same as of IP-67 one. 2.2 Package Content:  Ethernet switch  Console cable  Manual CD (by request)
  • Page 10: Ip Protection

    2.3 IP Protection The IP Code, Ingress Protection Rating, sometimes also interpreted as International Protection Rating, classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water in mechanical casings and with electrical enclosures. It is published by the International Electrotechnical Commission (IEC) Solid particle protection The first digit indicates the level of protection that the enclosure provides against access...
  • Page 11 Liquid ingress protection The second digit indicates the level of protection that the enclosure provides against harmful ingress of water. Protected Level Testing for Details against — — protected Dripping Dripping water (vertically Test duration: 10 minutes water falling drops) shall have no Water equivalent to 1 mm harmful effect.
  • Page 12 Powerful Water projected in powerful Test duration: at least water jets jets (12.5 mm nozzle) 3 minutes against the enclosure from Water volume: 100 litres per any direction shall have no minute harmful effects. Pressure: 100 kPa at distance of 3 m Immersion Ingress of water in harmful Test duration: 30 minutes...
  • Page 13: Led Indicators

    2.4 LED Indicators The diagnostic LEDs that provide real-time information of system and optional status are located on the front panel of the industrial switch. The following table provides the description of the LED status and their meanings for the switch. Color Status Meaning...
  • Page 14 The port is transmitting or receiving packets Blinking from the TX device. No device attached.
  • Page 15: Chapter 3 Hardware Installation

    Chapter 3 Hardware Installation 3.1Hardware installation 3.1.1Unpack switch and check the accessory with packing content list 3.1.2 Mount the switch on desired position. For the best ventilation, it is suggested to mount the switch on metallic surface. 3.1.3 Connect the M23/M12 connector of power input. The power supply for the series is connected via a 5-pole M23 female connector or a 5-pole M12 female connector depending on models.
  • Page 16 The power input voltage can be from 9.5V to 56VDC to feed power on both the 802.3af and 802.3at standardized devices. 24V model: The power input voltage can be from 12V to 56VDC to feed power on both the 802.3af and 802.3at standardized devices.
  • Page 17  The output voltage of power supply must exceed 48VDC for 802.3af and 53VDC for 802.3at operation (*with IPES-5416T-8-72V, only 72VDC can power both the 802.3af and 802.3at PD. **with IPES- 5416T-8-110V, only 110VDC can power both the 802.3af and 802.3at PD.
  • Page 18 Pin assignment of alarm relay A break in contact is reported via the relay contact :  The failure of at least one of the two supply voltages.  The break link status of at least one switch port. 3.1.4 Fitting the device, grounding Install the system in a dry and clean area to protect the switch to get exposed with dirt.
  • Page 19 Ground screw of IPES-5408T switch 3.1.5 Connect the M12 connector with RJ-45 data cable, ports are not used shall be caped that comes with the package to insulate the surrounding.
  • Page 20 Pin assignment of M12 10/100Tx network connector Pin assignment of M12 10/100/100T network connector (A-coded)
  • Page 21 Pin assignment of M12 10/100/100T network connector (X-coded) 3.1.6 Check the status of LED, make sure the switch was in working status. Note:  The protection class IP67/IP54/IP43 is only achieved when bolted together.  The other components attaching to the system have to meet with the IP67/IP54/IP43 protection class in order to reach the whole system IP 67/IP43 protection.
  • Page 22: Chapter 4 Network Application

    Chapter 4 Network Application 4.1 ITU G.8032 Scheme LANTECH G.8032 protocol is following ITU (International Telecommunication Unit) G.8032 v2 draft. The benefits of G.8032 are: 1. <50ms recovery time when failover 2. G.8032 has defined the protocol scheme, parameters, functions, test measures to be unified that the users can evaluate the possible network infrastructure without literally testing each brand in large scale.
  • Page 23: Multiple Rings

    4.3 Multiple Rings...
  • Page 24: Dual Homing

    4.4 Dual Homing 4.5 Chain...
  • Page 26: Chapter 5 Console Management

    Chapter 5 Console Management 5.1 Connecting to the Console Port The supplied cable which one end is M12 5-pole connector and the other end is RS-232 connector. Attach the end of RS-232 connector to PC or terminal and the other end of M12 connector to the console port of the switch.
  • Page 27 The settings of communication parameters Having finished the parameter settings, click ‘OK’. When the blank screen shows up, press Enter key to have the login prompt appears. Key in ‘admin’ (default value) for both User name and Password (use Enter key to switch), then press Enter and the Main Menu of console management appears.

Table of Contents