Installation - LEGRAND Pass & Seymour OSR300S Installation Instructions Manual

120/277vac dual relay pir wall switch
Table of Contents

Advertisement

INSTALLATION

CAUTION
TURN THE POWER OFF AT THE
CIRCUIT BREAKER BEFORE
INSTALLING THE SENSOR OR
WORKING ON THE LOAD.
1. Make sure that the power has been turned off at the circuit breaker.
2. Connect wires to the OSR300S wire leads as shown in the wiring diagrams.
The ground wires must be tightly fastened or the unit will not operate
properly. If the metal junction box is grounded, it can be a suitable ground.
Attach a ground wire to the green terminal as shown.
Strip Gauge
#12 – #14 AWG
Cu Wire Only
Insert or wrap ground wire as shown.
Tighten screw in the clockwise direction.
Neutral
Line
Black
Blue
Ground
Bi-Level Wiring
3. Attach the sensor to the wall box by inserting screws into the two wide holes
on the top and bottom of the attached metal bracket. Match them up with the
holes in the wall box and tighten.
4. Turn the circuit breaker on. Wait one minute, then push the Auto ON/OFF
switch for each load and the lights will turn on. There is a delay due to initial
power-up of the sensor that only occurs during installation.
Visit our website at www.passandseymour.com
White
Red
Primary
Load
Brown
Secondary
Load
WARNING
!
THE GROUND MUST BE TIGHTLY
SECURED OR THE SENSOR
WILL NOT WORK.
Neutral
Line 1 Black
Line 2
Blue
Ground
Neutral
Dual Circuit Wiring
!
Push–In
Screw Terminal
White
Red
Primary
Load
Brown
Secondary
Load
White