LEGRAND Pass & Seymour OS300S Installation Instructions Manual

LEGRAND Pass & Seymour OS300S Installation Instructions Manual

120/277vac pir wall switch

Advertisement

Quick Links

SPECIFICATIONS
Voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . .120/277VAC, 50/60Hz
Load Limits:
@120VAC . . . . . . . . . . . . . . . . . . .0-800W tungsten or ballast
@277VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0-1200W ballast
Load Type Compatibility . . . . . . . . . .incandescent, fluorescent,
Time Delay Adjustment . . . . . . . . . . . . . . . . . . .5 to 30 minutes,
Sensitivity Adjustment . . . . . . . . . . . . . . . . . . . . . . . .High or 50%
Alerts . . . . . . . . . . . . . . . .Selectable Audible and/or Light Flash
Horsepower Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/6 HP
OS300S
120/277VAC
PIR Wall Switch
magnetic or electronic ballast
user-selectable or automatic
US Patents: 4,787,722
Syracuse, NY 13221
4,874,962
800.223.4185

Advertisement

Table of Contents
loading

Summary of Contents for LEGRAND Pass & Seymour OS300S

  • Page 1 OS300S 120/277VAC PIR Wall Switch SPECIFICATIONS Voltages ......120/277VAC, 50/60Hz Load Limits: @120VAC ....0-800W tungsten or ballast @277VAC .
  • Page 2: Unit Description And Operation

    UNIT DESCRIPTION AND OPERATION The OS300S is a passive infrared wall switch that turns lighting ON and OFF based on occupancy and ambient light levels. SmartSet™ technology allows the sensor to be installed without any adjustments. This technology allows the sensor to automatically adjust to the usage patterns in the space.
  • Page 3: Sensitivity Adjustment

    Walk-Through Use for rooms that have frequent walk-through traffic Mode (ie. room that accepts mail deliveries). The OS300S turns the lights OFF three minutes after the area is initially occupied, if no motion is detected after the first 30 seconds. If motion continues beyond the first 30 seconds, the set time delay applies.
  • Page 4: Troubleshooting

    TROUBLESHOOTING Lights will not turn ON (LED does flash): 1. Press and release the button. If the lights turn ON, verify that the correct On Mode is selected in the DIP switches. 2. Check all wire connections, in particular, the Load connection. 3.
  • Page 5: Coverage Patterns

    COVERAGE PATTERNS The OS300S will cover up to 300 sq. ft. The typical recommended coverage for desktop activity is 150 sq. ft. The sensor has a two-tiered, multi-cell viewing Fresnel lens with 180 degree field of view. 4.0' (1.2m) floor (7.6m) (7.6m) (3.1m)
  • Page 6: Installation

    INSTALLATION WARNING CAUTION TURN THE POWER OFF AT THE THE GROUND MUST BE TIGHTLY CIRCUIT BREAKER BEFORE SECURED OR THE SENSOR WILL INSTALLING THE SENSOR OR NOT WORK. WORKING ON THE LOAD. 1. Make sure that the power has been turned OFF at the circuit breaker. 2.
  • Page 7: Sensor Adjustment

    ADJUSTMENTS Sensor Adjustment Your OS300S has been preset for optimum performance at the factory. It is designed with SmartSet technology for “Install and Forget” functionality. If you need to change the settings follow the directions below. All major adjustments to the OS300S must be made with the wall plate removed.
  • Page 8: Dip Switch Settings

    (1) by repair or replacement, or, at Pass & Seymour/Legrand’s option, (2) by return of an amount equal to the consumer’s purchase price. Such remedy is IN LIEU OF ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Table of Contents