Installation - LEGRAND 0 488 07 Manual

Pir detector switch

Advertisement

PIR detector switch
4. CONNECTION
Number of terminals: 4
Terminal type: automatic
Terminal capacity: 2 x 2.5 mm
2
Stripping length: 8 mm
Cabling with auxiliary control : Manual on/Auto off
100 m max.
Pressing the auxiliary control allows the load to be switched on or off
manually. If no action is performed on the control, the detector will cut
off the related load at the end of the time delay or when the Daylight
setpoint is reached.
Cabling without auxiliary control: Auto on/Auto off
The load will be switched on and off automatically.
Option: Detector control using infra-red remote control.
Wiring
Technical data sheet: S000100487EN_2
CONTENTS

5. INSTALLATION

Ø 68
8,5 A
max.
8,5 A
max.
6. DISASSEMBLY
Updated: 26/01/2023
Catalogue Number(s): 0 488 07
0.3 to 30 mm
Ø 65
CLIC
Created: 18/05/2010
2/4