Disposal; Technical Data; Input; Output - Endress+Hauser Soliswitch FTE20 Operating Instructions Manual

Point level switch
Hide thumbs Also See for Soliswitch FTE20:
Table of Contents

Advertisement

Technical data

10.4

Disposal

If required by the Directive 2012/19/EU on waste electrical and electronic equipment
(WEEE), the product is marked with the depicted symbol in order to minimize the disposal
of WEEE as unsorted municipal waste. Do not dispose of products bearing this marking as
unsorted municipal waste. Instead, return them to the manufacturer for disposal under the
applicable conditions.
11
Technical data
11.1

Input

11.1.1
Measured variable
Level (in line with the orientation and length)
11.1.2
Measuring range
The measuring range depends on the installation location of the device and the selected
length of the shaft 75 to 300 mm (2.95 to 11.81 in) or the rope extension up to max.
2 000 mm (6.56 ft).
11.2

Output

11.2.1
Output signal
Binary
11.2.2
Switch output
Function
Switch a floating changeover contact.
Switching behavior
On/off
Switching time
From rotary paddle standstill until output of the switch signal: 20°, corresponds to 3.5 s