Technical data
11.4

Performance characteristics

11.4.1
Shaft speed
-1
1 min
11.4.2
Sensitivity
Can be adjusted using an operating element accessible from the top →  29.
• Minimum: 80 g/l (4.99 lb/ft³)
• Depending on the density of the bulk solids adjustable in three stages: low, medium
(default), high
11.4.3
Mechanical operating life
500 000 switching operations
11.5

Mounting

11.5.1
Mounting location
Installation position →  2,  8
Permitted
Vertical from the top
Angled from the top
From the side
From the bottom (device must be
protected against shock-type
loads)
11.5.2
Special mounting instructions
Side load on the shaft
Max. 60 N
Load on the rope
Max. 1 500 N
Operating pressure (abs.)
0.5 to 2.5 bar (7.25 to 36.3 psi)
24
Not permitted
In direction of solids flow
Installation socket too long
Horizontal with shaft length
>300 mm (11.8 in)
Soliswitch FTE20
Comments
Cable entry must point
downwards
Cable entry must point
downwards; with protective cover
against falling solids depending
on the installation position
Cable entry must point
downwards
Endress+Hauser