Close Direction - Genie GCL-MJ Manual

Medium duty operator
Hide thumbs Also See for GCL-MJ:
Table of Contents

Advertisement

Setting Close Direction:
The direction of motor rotation depends on mounting position and/or how the main input power phases are
wired. This setting is used to ensure the door is closing and opening according to the input commands.
NOTE: Make sure door is in mid-travel.
1. If operator is in RUN mode, press CAL/RUN key to enter CALIBRATION MODE.
2. Use the SCROLL Key to scroll through the menu until SET CLOSE DIR is displayed. Press SET/CLR key.
3. Display will read HIT CLOSE KEY TO TEST. Briefly press the CLOSE key. FIG. 2 (Pressing the Scroll key at this
point will exit this function). * The display will read DID DOOR CLOSE >YES< NO FIG. 3.
4. Press SCROLL key (up or down) to toggle between YES and NO. FIG. 4. If YES is selected, no change to
operator calibration is made. If NO is selected, the board will change the operator's down direction.
5. Press the SET/CLEAR key to make the selection. Display will read CLOSE DIR > SET and then UP LIMIT >
CLR.
6. Press CAL/RUN to return to run mode, or continue with LIMIT programming on next page.
SET CLOSE DIR
CAL
RUN
HIT CLOSE KEY TO
CAL
RUN
Section 4: Programming
OPEN
CLOSE
STOP
SET
SCROLL
CLEAR
SCROLL
FIG. 1
OPEN
CLOSE
STOP
SET
SCROLL
CLEAR
SCROLL
FIG. 2
TEST
SCROLL KEY
DID DOOR CLOSE?
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
FIG. 3
YES
NO
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
FIG. 4
OPEN
CLOSE
STOP
OPEN
CLOSE
STOP
Sec-4.3