Troubleshooting guide

Problem
Error Code
Possible Cause
1. Water tap is not open.
The machine
2. Drain hose is too low.
"E01"
fills overtime.
3. Water inlet valve is damaged.
1.The door is not locked properly.
2. Garment is caught between the
Door lock
"E02"
alarm sounds
door and seal.
3. Door lock is damaged
1. The drain hose is squashed or
kinked.
The machine
"E03"
2. The drain pump filter is blocked.
drains overtime.
3. The drainage system pipes are
blocked.
1. The water inlet valve is damaged.
Water overflow.
2. The connection between the water
Water sensor
"E04".
works
sensor and wire is not secure.
abnormally.
3. The water sensor is damaged.
1. The connection between the motor
and wire is not secure.
The motor does
"E05"
not work.
2. The motor has over-heated.
3. The motor is damaged.
1. The connection between the
Heating tube
"E06"
fault.
heating tube and wire is not secure.
2. The heating tube is damaged.
1. The connection between the
temperature sensor and wire is not
Temperature
secure.
"E07"
sensor fault.
2. The temperature sensor is
damaged.
There is a
"E09"
1.The signal transmission failed.
signal faut
1. The connection between the
Inverter fails
inverter and wire is not secure.
"E10"
to start
2. The inverter is damaged.
High AC
"H:AC"
1. The voltage of AC is too high.
voltage
Low AC
1. The voltage of AC is too low.
"L:AC"
voltage
Difficult explanation
1. Open the water tap.
2. Hook up the hose.
3. Change the water inlet valve.
1. Ensure the door is fully closed.
2. Put the garment into the drum.
3. Change the door lock.
1. Check the drain hose.
2. Clean the filter.
3. Check the drainage system and
clean it.
1. Change the water inlet.
2. Check the connection is secure.
3. Change the water sensor.
1. Check the connection is secure.
2. Check if the machine is overloaded.
Switch off the machine, and retry
when the motor has cooled down.
3. Change the motor.
1. Check the connection is secure.
2. Change the heating tube.
1. Check the connection and ensure
it is secure.
2. Change the temperature sensor.
1.Restart the machine
1. Check the connection and ensure
it is secure.
1. It will be ok one the voltage return
to normal.
1. It will be ok one the voltage return
to normal.

Technical Parameters

Model
Parameter
Power
Washing / spin capacity
Rated power
Water pressure
Power of off-mode
Power of left-on mode
Program time(min)
Remaining moisture content
Average Energy consumption
Average Water consumption
Net weight / gross weight
Outer dimension
(W x D x H)mm
Note:
Data can vary from the nominal values given depending on water pressure, water
hardness, water inlet temperature ,room temperature, type and volume of load,
fluctuations in the electricity supply and any extra options selected.

Electric Diagram

Appendix
WMUK004W
220V-240V~,50HZ
10.0kg
2000W
0.02-0.8MPa
0.38W
0.38W
304
Class B
1.05kWh
54.5L
69kg/74kg
595X665X845mm