98648-006-98 98648-006-98 Sartorius Basic Sartorius Basic plus plus Electronic Semi-micro-, Analytical Electronic Semi-micro-, Analytical and Precision Balances and Precision Balances Installation and Operating Instructions Installation and Operating Instructions...
Page 4
Contents Contents Page Page Page Page G G e e n n e e r r a a l l V V i i e e w w s s o o f f t t h h e e B B a a l l a a n n c c e e s s T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g G G u u i i d d e e 2 2 6 6 W W a a r r r r a a n n t t y y...
Page 5
Page Page Application Programs ISO/GLP-compliant Printout Tare Memory or Record Practical Example: Printout/Record for Tare – Net – Gross Weights Adjustment or Calibration and Practical Example: Net Total Linearization Functions Weighing in Percent Data Printout/Record Practical Example: Determination (ISO/GLP-compliant) of the Residual Weight in Percent 44 Data Printout/Record for Counting Application Programs...
Page 6
BP 211D, BP 211D-0CE 17 7 No. Designation Order no. for No. Designation Order no. for replacement replacement 1 Weighing pan 69 B20116 12 Weight display 2 Shield disk 69 B20117 13 DC jack 3 Metrological ID label 14 Verification ID label with metrological for verified balances approved data for verified balances approved for use as legal measuring instruments...
Page 7
BP 301S,BP221S,BP161P,BP121S,BP61S,BP 301S-0CE, BP221S-0CE,BP161P-0CE,BP121S-0CE,BP61S-0CE 17 7 No. Designation Order no. for No. Designation Order no. for replacement replacement 1 Weighing pan 69 B20116 12 Weight display 2 Shield ring 69 B20117 13 Verification ID label with metrological 3 Metrological ID label data for verified balances approved for verified balances approved for use as legal measuring instruments...
Page 8
BP 410 S, BP 310 S, BP 310 P, BP150, BP 410 S-0CE, BP 310 S-0CE, BP 310 P-0CE,BP150-0CE, BP 110-0CE 17 7 No. Designation Order no. for No. Designation Order no. for replacement replacement 1 Weighing pan 69 B20002 13 Verification ID label with metrological 2 Shield ring 69 B20015...
Page 10
BP 41 4100 00 S S , , BP BP 3 3 1 1 00 00 S S , , BP BP 3 3 1 1 00 00 P P , , BP BP 2 2 1 1 00 00 S S , , BP BP1 1 200 200, , BP BP 3 3 1 1 00...
Page 11
BP BP 8 8 1 1 00 00, , BP BP 6 6 1 1 00 00, , BP BP4 4 1 1 00 00, , BP BP 2 2 1 1 00 00, , BP BP 8 8 , , BP BP 8 8 1 1 00-0C 00-0CE, E, BP BP 6 6 1 1 00-0C 00-0CE, E, BP BP 8-0CE...
Page 12
BP16000 S, BP12000 S, BP 34000 P, BP 34 17 7 No. Designation Order no. for No. Designation Order no. for replacement replacement 1 Weighing pan 69 LC0107 12 Weight display 4 Menu access switch 14 DC jack 5 Leveling foot 69 LC0092 15 Manufacturer’s label with 6 Zero-setting and tare keys...
Page 13
Do not miss out on the benefits of our full warranty. Please complete the warranty registration card, indicating the date of installation, and return the card to your Sartorius office or dealer. Storage and Shipping Conditions Allowable storage temperature: +5°C …+40°C +41°F…+104°F...
Installation Instructions Ambient Conditions When choosing a location to set up your balance, observe the following: – Set up the balance on a stable, even surface (benchtop or floor), or place it on a wall console (see “Accessories”) – Avoid placing the balance in close proximity to a heater or otherwise exposing the balance to extreme heat or to direct sunlight –...
Page 15
Using Verified Balances as Legal Measuring Instruments in the EU* You must calibrate the balance at the place of installation before using it as a legal measuring instrument (see the section entitled “Adjustment/ Calibration” starting on page 22). This balance is not allowed to be used for weighing goods intended for direct sale to the public.
Legal regulations require the verified balance to be sealed. This control seal consists of an adhesive label with the name “Sartorius” on it. This seal will be irreparably damaged if you attempt to remove it. In this case, the validity of the seal becomes void and you must have your balance re-verified.
Page 17
Preparing Balances with a Round Weighing Pan – Place the shield disk (2) on the balance. Turn the disk counterclockwise until it stops and is secured. Place the components listed below on the balance in the order given: – Pan support (21) –...
Page 18
Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by Sartorius AG could void the user’s authority to operate the equipment.
Page 19
Connecting Electronic Peripheral Devices Make absolutely sure to unplug the balance from AC power before you connect or disconnect a peripheral device (printer or PC) to or from the interface port. Adjusting the Display Unit on Balances with a Weighing Capacity of 10 kg ≥...
Page 20
Leveling the Balance Using the Level Indicator At the place of installation, level the balance using the leveling feet (5) so that the air bubble is centered within the circle of the level indicator (17) . For balances with a rectangular pan and a weighing capacity of <10 kg: Retract the two auxiliary feet located at the back ...