Pump Installation and Service Manual HPG200V Packages Installation & Service Manual with Parts List 2 HP Grinder Pump and Control Panel NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system.
Page 2
OUTSIDE BLOWER IS USED. TO FORCE FRESH AIR MUST BE INSTALLED BY EXPERIENCED INTO THE BASIN. ALSO, THE WORKER IN THE PROFESSIONALS ONLY BASIN MUST WEAR A HARNESS ATTACHED TO THE SURFACE SO THAT HE CAN BE PULLED OUT IN CAUTION: READ THESE SAFETY WARNINGS FIRST CASE OF ASPHYXIATION.
Page 3
PUMP 1. Pump builds up heat and pressure during opera- LEVEL SENSING CONTROLS tion, allow time for pump to cool before handling or Intrinsically-safe type float controls are recommended for servicing. all applications and required for explosion-proof service. An intrinsically safe control panel relay will limit the 2.
Page 4
PACKAGING — Each pump is packaged with 10 feet of Pump has two oil-filled chambers: (1) the motor and power cord in a carton that is marked with Model ball bearings and (2) the seal chamber - for long life and Number and Engineering Number.
Page 5
VARIABLE SPEED AC MOTOR DRIVE The SCF Sub-Micro Drive Input Power Terminals Ground Lug Electronic Programming 3-Digit LED Module (EPM) Display Programming Buttons Control Terminal Strip Output (Motor) Terminals TROUBLESHOOTING THE SCF DRIVE Press Mode once Display reads "00" To aid in troubleshooting, Parameters 50 through 60 can be accessed without entering the PASSWORD.
Page 6
SCF DRIVE FAULT CONDITIONS The table below lists the fault conditions that will cause the drive to shut down, as well as some possible causes. Please contact the factory for more information on troubleshooting faults. FAULT DESCRIPTION & POSSIBLE CAUSES High Temperature Fault: Ambient Temperature is too high;...
Page 7
SCF DISPLAY MESSAGES SPEED SOURCE DISPLAYS DISPLAY DESCRIPTION The following describes the various displays and messages CONTROL PAD: Speed is set using the that can appear on the SCF drive. buttons on the front of the drive. EXTERNAL CURRENT: Speed is controlled by a SPEED DISPLAY 4-20 mA signal wired to TB-25 and TB-2 EXTERNAL VOLTAGE: Speed is controlled by a...
Page 8
REPLACING GRINDER IMPELLER AND GRINDER SHREDDING RING This is the only disassembly operation allowed in the field. All other repair must be done at the factory or at an authorized service station. Standard Tools Required: 1. Allen head socket set 2.
Page 9
6. Be sure pump impeller has not loosened when grinder impeller is removed. This can be checked on reassembly of grinder impeller and shredding ring. Tips of impeller cutter vanes should extend about 1/8” below bottom of shredding ring. If distance is more, it means the pump impeller has loosened, and if it is less, it means the shredding ring is not properly seated.
TROUBLE CHECK LIST Troubles listed below are generally not caused by the pump. Other trouble can occur from faulty control box operation. These will be listed with the control box instructions. CONDITION PROBABLE CAUSE Pump runs but does not pump 1.
Page 11
Circuit breaker trips 1. Reset breaker by pushing clear down on handle then back to “ON” position. If breaker trips again in few seconds it indicates excessive load probably caused by a short in the motor or control box. Check out instructions given with control box before pulling pump.
MOTOR WIRING DIAGRAM Motor Electric Data TO PANEL TO PUMP PHASE AMPS PHASE AMPS Model HP VOLTS HERTZ RUN KW HPG200V 12.2 PERFORMANCE CURVE Capacity Liters Per Minute Capacity Gallons Per Minute...
STANDARD LIMITED WARRANTY ® warrants its products against defects in material and workmanship for a period of 12 months from the date HYDROMATIC of shipment from Hydromatic or 18 months from the manufacturing date, whichever occurs first - provided that such products are used compliance with the requirements of the Hydromatic catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive free non-corrosive liquids.