May. 2010
SECTION 6
6-1 PREPARATION
¤ REQUIRED EQUIPMENTS
EQUIPMENT
Adjustment
"CS-FR5000" (All models except [DPM-01])
Software
"CS-FR5000(dPMR)" [DPM-01]
Output voltage
Current capacity
Power Supply
Measuring range
RF Power Meter
Frequency range
(terminated type)
Impedance
SWR
Frequency range
Frequency Counter
Frequency accuracy : ±1 ppm or better
Input level
Modulation
Frequency range
Analyzer
Measuring range
¤ JIG CABLE
OPC-1122U
(USB type Cloning cable)
Add a jumper wire here
(Replacement page)
ADJUSTMENT PROCEDURE
SPECIFICATION
: 13.6 V DC [FR5000]
13.2 V DC [FR5100]
: More than 20 A
[FR5000]
More than 10 A
[FR5100]
: 1–60 W
[FR5000]
1–30 W
[FR5100]
: 100–300 MHz
: 50 Ω
: Less than 1.2 : 1
: 0.1–300 MHz
: Less than 1 mW
: 30–300 MHz
: 0 to ±10 kHz
EXT. SPEAKER
(5 W/4 Ω)
−
GND
SP
GND
MIC
GND
PTT
PTT
6 - 1
EQUIPMENT
Modifi ed OPC-1122U (USB type)
JIG cable
(see the illust below)
Power attenuation : 40 dB
Capacity
Attenuator
Frequency range
Standard Signal
Output level
Generator (SSG)
Frequency range
Audio Generator
Output level
AC Millivoltmeter
Measuring range
Frequency range
Oscilloscope
Measuring range
Input impedance
External Speaker
Capacity
AUDIO GENERATOR
(300–3000 Hz/1–100 mV)
+
+
4.7 µF
SPECIFICATION
: More than 60 W
[FR5000]
More than 30 W
[FR5100]
: 0.1–300 MHz
: 0.1 mV to 32 mV
(–127 to –17 dBm)
: 300–3000 Hz
: 1–500 mV
: 10 mV to 10 V
: DC–20 MHz
: 0.01–20 V
: 4 Ω
: More than 5 W
AC MILLIVOLT METER
(10 mV to 10 V)
+ −
+ −
Need help?
Do you have a question about the IC-FR5000 and is the answer not in the manual?
Questions and answers