XYJGT6070UDE-002
1、 用 13 号外六角套
筒配合电批拆除左
使用工具
图上配重块螺钉 1、 2
Using tools
Remove the screws
1 and 2 of the upper
balancer with No.13
1
outer hexagon
sleeve and electric
2
screwdriver, and
take out the
13 号外六角套
balancer
No.13 outer
hexagon sleeve
2、拆出的配重块要
轻拿轻放,避免损坏
Remove the upper
balancer to be
handled gently to
avoid damage
3
电批
Electric
3、拔出水位传感器
screwdriver
接线端子 3,把水位
传感器向上移,拆下
水位传感器
Pull out the water
level switch terminal
3, move the water
level sensor upward
and remove the
water level sensor
拆除减震销和排水软管
Remove absorber pin and drain hose