STRETCHER SUPPORT SERIES PB-410
Review 2022/01
01
INTRODUCTION
7. Crushing injuries could arise from sideways or extraction movements of the stretcher support. Always
ensure that nothing interferes with the stretcher support before moving it.
8. Loading of the stretcher on the stretcher support, especially if the device is in tilted position, could need
great effort from the operator, resulting in injuries. Pay attention during loading and unloading of the stret-
cher and, in case of heavy weight, consider that at least 2 operators are required.
9. The operation of any movement of the device when the vehicle is running, could result in extremely vio-
lent movements in case the vehicle has an impact. It is recommended to make the adjustments only when
the vehicle is not moving

01.12 Reference standards

REFERENCE
TITLE OF DOCUMENT
Patient handling equipment used in road ambulances. Part 1. Table support
UNI EN ISO 1865-5
brancard.
UNI EN 1789
Medical vehicles and their equipment. Road ambulances
As a distributor or end user of the products manufactured and/or distributed by Promeba,
S.L., you are strictly obliged to know the legal provisions in force in the country of destination
of the goods, applicable to the devices to be supplied (including the regulations relating to
technical specifications and/or safety requirements) and, therefore, understand the necessary
requirements to ensure compliance of the products themselves with all the legal requirements
of the territory.
01.13 Life span
If used as described in the following instructions, this device has a useful life of 10 years from the date
of purchase.
This useful life can be extended with annual reviews carried out by the manufacturer, which uses speciali-
zed and authorized internal and external technicians.
In case these annual checks are not carried out, the device must be disposed of according to the informa-
tion in paragraph 01.4 and the manufacturer must be notified.
Only the manufacturer or an authorized center can extend the life of the device, if it meets the safety requi-
rements.
Promeba, S.L. will not accept any responsibility for malfunction or damage caused by the use of devices
that have not been checked by the manufacturer or authorized center, or that have exceeded the maximum
allowed useful life.