Power Requirements:
Battery Operation:
Enclosure Type, Size:
Operating Environment: Temperature: 14 to 104 ºF (-10 to +40 ºC)
Display:
Sensitivity:
Signal Input Range:
Transducer Excitation:
(Jumper selectable)
Number of Load Cells:
Load Cell Cable Length: 1500 feet maximum. Consult factory for other requirements
Resolution:
Capacities:
Tare Capacity:
Division Value:
Sample Rate:
Auto Zero Range:
Weighing Units:
Keypad:
Standard I/O:
(1) Bi-directional RS232 and 20mA and (1) RS232/20mA output only
Optional I/O:

Standard Features:

• Push button tare function
• Selectable key disable
• Adjustable filtering
• Remote input lines for Zero, Tare, Gross and Print (1000 feet maximum)
• Programmable print format using Visual Print (2, available )
• SMA level 2 compliant serial communications
(For more information see http://www.scalemanufacturers.org)
• Field re-programmable via PC interconnection
• Test feature (performs display and internal tests)
• Battery Operation and Auto Shutoff & Sleep mode ( Models 205 and 210 only )
Additional Model 210 Standard Features:
• Keypad tare function
• Three Preset Weight Comparators or Checkweigher (setup selectable)

Optional Features:

• Column Mounting available ( Models 205 and 210 )
• Analog Output ( All Models )

SPECIFICATIONS

90 to 264 VAC (50/60 Hz) at 0.4A
( Models 205 and 210 only ) CAM-350 Type 12 volt 2000 mAh (2.0 Ah)
Model 200 - Panel Mount, NEMA 12/IP52:
5 11/16"W x 2 13/16"H x 7 7/8"D (144mm W x 72mm H x 200mm D)
Models 205/210 v- NEMA 4X/IP66:
9 3/16"W x 7 1/2"H x 3 1/8"D (233mm W x 191mm H x 79mm D)
Weight: 8.2lbs - (9.6lb with battery)
Humidity: 90% non-condensing (maximum)
6-digit, 0.6" high, 7-segment LED
0.056 uV/V/d (0-3.3 mV/V input)
This equipment is manufactured in accordance with recommendations
set for a Class III device by the National Conference on Weights and
Measures, Measurement Canada and OIML R-76.
1.0 mV min. to 40 mV max. (with dead load boost)
12 VDC ( all models )
8 VDC - Battery operation ( Models 205 and 210 only )
8 each, 350 OHM minimum resistance
30 feet maximum without sense lines
1 part in 100,000 displayed, normal mode
1 part in 1,000,000 internal
100 to 10,000 divisions commercial,
Up to 200,000 divisions non-commercial
Scale Capacity
1, 2, or 5 x 10, 1, 0.1, 0.01, and 0.001, commercial
0 to 99, non-commercial
1 to 50 samples per second, selectable
0.5 or 1 through 9 divisions
Tons, Pounds, Pounds-Ounces, Ounces, Metric Tons, Kilograms, Grams
Membrane type with 7 color-coded keys (22 keys on Model 210)
14 bit Analog Output (0 to 10v, 4 to 20mA)
• Gross, tare, net conversion
• Hi-Resolution mode
• Gross and Net accumulators
• Count feature
• Special Filtering ( All Models )
3
• Time and Date

Advertisement

Table of Contents
loading

This manual is also suitable for:

200205210