Cardinal 200 Series Installation, Technical And Operation Manual page 28

Weight indicating instrument
Hide thumbs Also See for 200 Series:
Table of Contents

Advertisement

SETUP AND CALIBRATION, Cont.
*
If SB-400
or Computer is selected, the data will be transmitted in the following format:
<s><xxxxxx><d><uu><m><cc><cr>
Where:
s =
Sign
xxxxxx.xxx = Weight
d =
Decimal point
uu =
Units
m =
Mode
cc =
Weight Status
cr =
Carrriage Return
*
The SB-80, SB-300 ( multiple displays not supported ) and WinVRS use the SB-400 format.
If SB-200 is selected, the data will be transmitted in the following format:
<cr><s><xxxxxx><d><c><uu><m> ETX
Where:
cr =
Carrriage Return
s =
Sign
xxxxxx.xxx = Weight
d =
Decimal point
c =
status
uu =
Units
m =
Mode
ETX =
End of TeXt
If Rice Lake IQ355 is selected, the data will be transmitted in the following format:
<stx><polarity><wwwwwww><units><g/n><status><crlf>
Where:
stx =
Start of TeXt
polarity =
Sign
wwwwwww =
Weight
units =
Units
g/n
Mode
status
status
CRLF =
Carrriage Return
with Line Feed
"-" = negative, " " ( blank ) = positive
Six digits
Added to string if enabled in setup
tn, lb, l/o, oz, t, kg, g
G = Gross, N = Net
OC = overcap
BZ = below zero
MO = motion
ee = weight not currently being displayed
(hex 0D)
(hex 0D)
"-" = negative, " " ( blank ) = positive
(with leading zeros)
Embedded into weight (after weight dpp=0)
m = motion
o = overcap
e = weight not currently being displayed
tn, lb, l/o, oz, t, kg, g
G = Gross, N = Net
(hex 03) MUST terminate ALL serial commands
(hex 02)
"-" = negative, " " ( blank ) = positive
Seven digits
" "( blank ) = none, L = lb, K = kg, T = tons,
G = grams, O = ounces
G = Gross, N = Net
" "( blank ) = valid
I = invalid
M = motion
O = overcap
(hex 0D) with (hex 0A)
27