SETUP AND CALIBRATION, Cont.
A oFF= (Auto Shutoff) - Models 205 and 210 Only
The Automatic Shutoff feature will automatically turn the indicator off (when it is not in use) after a
predetermined period of inactivity to prolong battery life. To turn the instrument back on you must
press the ON / OFF key.
Press the ENTER key to show the current status for this feature. A number other than 0 indicates
that the auto shutoff feature is enabled and the displayed number corresponds to the number of
minutes of stable weight displayed before the indicator is turned off automatically. Note that a 0
indicates the feature has been turned off. If the setting displayed is acceptable, press the ENTER
key again to save it. Otherwise, use the numeric keys to enter a new value (0 to 10) then press
the ENTER key to store the new setting.
CLtAr= (Clear Tare)
The Clear Tare feature allows the indicator to clear the Stored Tare weight when the Net weight
goes below zero (a negative net weight after display of a positive net weight). With this feature
enabled, the operator must re-set the tare after completion of a transaction when the load
(container plus item) is removed from the scale.
Press the ENTER key to show the current value. If the setting displayed is acceptable, press the
ENTER key again to save it. Otherwise, using the numeric keys, 0/NO or 1/YES, enter the new
setting, then press the ENTER key to save it.
CLtAr = 1 (Yes)
Automatically clears Stored Tare
when Net weight goes below zero
The following is a typical example of the Clear Tare feature in use .
1. Place container on scale, then press TARE key (with diamond "T" symbol on 210).
2. Load container with item to be weighed and perform normal weighing operation.
3. Remove load (item AND container) from scale.
4. Scale weight returns to below zero (the weight of the container) and is then reset to zero.
5. Operator is required to repeat step 1 before next weighing operation.
A - d (A - d?) - Analog to Digital Filtering
dFLt= (Digital Filtering)
With A - d (A - d?) displayed, press the ENTER key. The display will change to dFLt=. Press the
ENTER key to show the current value. If the setting displayed is acceptable, press the ENTER key
to save it. Otherwise, using the numeric keys enter the new setting, then press the ENTER key to
save it. Allowable values are: 0, 1, 2 or 3. Note, that if you select 3 (Custom Filtering) two
additional prompts will be displayed.
dFLt=
0
Disabled – NO Filtering
1
MINIMAL FILTERING (sample rate = 2)
2
MODERATE FILTERING (sample rate = 1)
3
CUSTOM FILTERING
NOTE! The prompts, F= (Filter Level) and b= (Break Range) will only be displayed if you
selected 3 (Custom Filtering) for the dFLt= (Digital Filtering) prompt.
F= (Filter Level)
Press the ENTER key to show the current setting for the filter level. The filter level is a number
from 1 to 99 that corresponds to the level of filtering with 99 being the greatest filtering and 1 the
least. To accept the value displayed, press the ENTER key, otherwise, use the numeric keys to
enter a new value then press the ENTER key to save it.
CLtAr = 0 (No)
Stored Tare is not cleared when
Net weight goes below zero
23