CO Alarm-Control
Power supply
Type of apparatus
Battery life
Lifespan under typical conditions
CO concentration measurement range
Measuring accuracy
Alarm response times on default settings
Alarm siren sound level
Operating temperature
Operating humidity
Dimensions (d x h)
Radio frequency of individual device must be same as your Z-Wave controller. Check information on the box or consult your dealer if you
are not sure.
Using batteries other than specified may result in explosion. Dispose of properly, observing environmental protection rules.
Replace the device before date on the front or if sensor error is detected.
Radio transceiver
Radio protocol
Frequency band
Transceiver range
Max. transmit power
(*) The transceiver range is strongly influenced by other devices operating at the same frequency with continuous transmission, such as alarms
and radio headphones which interfere with the control unit transceiver.
CR123A 3.0V battery (included)
3 years on default settings (tested with Panasonic Industrial Lithium)
±10ppm / ±5%
50ppm 60-90min; 100ppm 10-40min; 300ppm <1.5min
85 dBA at 3 meters (10 feet)
10-95%RH without condensation
Z-Wave (500 series chip)
868.4 or 869.8 MHz (EU)
921.4 or 919.8 MHz (ANZ)
up to 50m outdoors
up to 40m indoors
(depending on terrain and building structure)
up to -5 dBm (EIRP)
Type B
8 years
0 - 450 ppm
0 - 50°C
65 x 28 mm