Parameter:
Description:
Available settings:
Default setting:
Parameter:
Description:
Available settings:
Default setting:
Parameter:
Description:
Available settings:
Default setting:
Notes:
Setting parameters 11, 12, 16, 19 to appropriate value will result in:
» 0 - turning associated devices off,
» 1-99 - forcing level of associated devices,
» 255 - setting associated devices to the last remembered state or turning them on.
Parameter 14 value must be at least 4 ppm higher than parameter 17 value.
Parameter 17 value must be at least 4 ppm lower than parameter 14 value.
Values received by the controller may be used for graphs of CO concentration level.
Parameter 25 is closely related to parameter 26.
23. CO meter activation
This parameter activates reporting the value of CO concentration level to the main Z-Wave controller.
0 - disabled
1 - enabled
1 (enabled)
25. CO level reporting hysteresis
This parameter defines a minimum change in CO concentration level which results in sending a new value to the
main Z-Wave controller.
2-6 (10 ppm - 30 ppm, each 5 ppm)
2 (10 ppm)
26. Threshold of CO meter activation
This parameter defines the CO concentration level, which exceeding will result in sending a new value to the main
Z-Wave controller, according to parameter 25 settings. Adjusting the value allows to get the accurate data in case
of danger and helps to save the battery in normal conditions.
10-255 (ppm)
30 (30 ppm)
Parameter size:
1 [byte]
Parameter size:
1 [byte]
Parameter size:
2 [bytes]