Parameter:
Description:
Available settings:
Default setting:
Parameter:
Description:
Available settings:
Default setting:
Parameter:
Description:
Available settings:
Default setting:
Notes:
•
Setting parameters 11, 12, 16, 19 to appropriate value will result in:
» 0 - turning associated devices off,
» 1-99 - forcing level of associated devices,
» 255 - setting associated devices to the last remembered state or turning them on.
•
Parameter 14 value must be at least 4 ppm higher than parameter 17 value.
•
Parameter 17 value must be at least 4 ppm lower than parameter 14 value.
•
Values received by the controller may be used for graphs of CO concentration level.
•
Parameter 25 is closely related to parameter 26.
23. CO meter activation
This parameter activates reporting the value of CO concentration level to the main Z-Wave controller.
0 - disabled
1 - enabled
1 (enabled)
25. CO level reporting hysteresis
This parameter defines a minimum change in CO concentration level which results in sending a new value to the
main Z-Wave controller.
2-6 (10 ppm - 30 ppm, each 5 ppm)
2 (10 ppm)
26. Threshold of CO meter activation
This parameter defines the CO concentration level, which exceeding will result in sending a new value to the main
Z-Wave controller, according to parameter 25 settings. Adjusting the value allows to get the accurate data in case
of danger and helps to save the battery in normal conditions.
10-255 (ppm)
30 (30 ppm)
Parameter size:
1 [byte]
Parameter size:
1 [byte]
Parameter size:
2 [bytes]