Nice CO Alarm-Control Instructions And Warnings For Installation And Use page 9

Table of Contents

Advertisement

Parameter:
13. Commands sent to 4th association group (CO Level)
Description:
This parameter defines commands sent to devices associated in 4th association group (CO Level). Values of
specified commands may be set in parameters 16 and 19.
Available settings:
1 - BASIC ON
2 - BASIC OFF
3 - BASIC ON & BASIC OFF
Default setting:
3 (ON & OFF)
Parameter:
14. CO level required for sending BASIC ON command to 4th association group
Description:
This parameter defines the minimum level of CO concentration which exceeding will result in starting the timer set
in parameter 15.
Available settings:
25-400 - CO concentration level in ppm
Default setting:
40 (40 ppm)
Parameter:
15. Time required for sending BASIC ON command to 4th association group
Description:
This parameter defines the time during which the level of CO concentration should remain above the value set in
parameter 14 to send the BASIC ON command to 4th association group.
Available settings:
0 - immediate sending of BASIC ON command
1-2880 (30s - 24h, in 30s steps)
Default setting:
0
Parameter:
16. Value of BASIC ON command sent to 4th association group
Description:
This parameter defines the value of BASIC ON command sent to devices in 4th association group after exceeding
the CO level set in parameter 14 through the time set in parameter 15.
Available settings:
0-99 or 255
Default setting:
255 (turn on)
Parameter:
17. CO Level required for sending BASIC OFF command to 4th association group
Description:
This parameter defines the level of CO concentration below which falling will result in sending the BASIC OFF
command to 4th association group.
Available settings:
10-400 - CO concentration level in ppm
Default setting:
25 (25 ppm)
Parameter:
19. Value of BASIC OFF command sent to 4th association group
Description:
This parameter defines the value of BASIC OFF command sent to devices in 4th association group after falling
below the CO level set in parameter 17.
Available settings:
0-99 or 255
Default setting:
0 (turn off)
Parameter:
20. Temperature reporting time interval
Description:
Time interval (in seconds) between consecutive reports of temperature (done by built-in temperature sensor).
Short time interval means more frequent communication, which results in shortened battery life.
Available settings:
0 - no periodical reports
10-1440 (5min - 12h, in 30s steps)
Default setting:
0
Parameter:
21. Temperature reporting hysteresis
Description:
This parameter defines a minimum change in temperature resulting in a report being sent to the main Z-Wave
controller.
Available settings:
1-20 (0.5°C - 10°C, each 0.5°C)
Default setting:
2 (1°C)
Parameter:
22. Threshold of exceeding the temperature
Description:
This parameter defines the temperature level, which exceeding will result in sending actions set in parameters 2, 3
and 4.
Available settings:
1-85 (1°C - 85°C, each 1°C)
Default setting:
55 (55°C)
Parameter size:
1 [byte]
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]
Parameter size:
1 [byte]
Parameter size:
1 [byte]