SiteTech Group
Voltage Regulator
Voltage Regulator
Voltage Regulator
Engine Timing
Engine Timing
Engine Timing
Engine Timing
Engine Timing
Genset Protection
Genset Protection
Genset Protection
Genset Protection
Genset Protection
Genset Protection
Engine Protection
Engine Protection
Engine Protection
Generator Protection
Generator Protection
Digital Input B1 †
Digital Input B1 †
Digital Input B1 †
Digital Input B2 †
Digital Input B2 †
Digital Input B2 †
Digital Output B1 †
Digital Output B1 †
Digital Output B2 †
Digital Output B2 †
Digital Output B3 †
Digital Output B3 †
Digital Output B4 †
Digital Output B4 †
Digital Output B5 †
34
Section 3 Controller
Parameter
Voltage Regulator Average Voltage
Adjustment
Voltage Regulator Volts Per Hertz Slope
Voltage Regulator Gain
Engine Start Delay
Engine Cool Down Delay
Engine Crank On Delay
Engine Crank Pause Delay
Engine Number Of Crank Cycles
Genset Low Battery Voltage Warning Delay
Genset High Battery Voltage Warning Delay
Genset Low Battery Voltage Warning Limit
Genset High Battery Voltage Warning Limit
Genset Battery Low Cranking Voltage
Warning Delay
Genset Battery Low Cranking Voltage
Warning Limit
Engine Locked Rotor Shutdown Delay
Genset Low Engine Speed Shutdown Limit
Genset High Engine Speed Shutdown Limit
Genset High Voltage Shutdown Delay
Genset High Voltage Shutdown Limit
Digital Input B1 Value
Digital Input B1 Enabled
Digital Input B1 Event
Digital Input B2 Value
Digital Input B2 Enabled
Digital Input B2 Event
Digital Output B1 Value
Digital Output B1 Event
Digital Output B2 Value
Digital Output B2 Event
Digital Output B3 Value
Digital Output B3 Event
Digital Output B4 Value
Digital Output B4 Event
Digital Output B5 Value
Adjustment
Units
Range *
V
24–64 (Auto
select with
system voltage)
%
1–10
1–255
s
0–300
s
300–600
s
10–30
s
1–60
1–6
s
Read Only
s
Read Only
%
80–100
%
110–135
s
Read Only
%
Read Only
s
3
%
75–95
%
105–120
s
Read Only
%
Read Only
Read Only
True or False
See dropdown
list in SiteTech
Read Only
True or False
See dropdown
list in SiteTech
Read Only
See dropdown
list in SiteTech
Read Only
See dropdown
list in SiteTech
Read Only
See dropdown
list in SiteTech
Read Only
See dropdown
list in SiteTech
Read Only
Default Setting
27, 40.5, or 54
(System Voltage)
5
128
0
300
15
15
3
90
10
100
125
6
60
3
85
115
2
120
False
False
PIM: None; (0)
Comm Kit: Fuel
Pressure Switch
False
False
PIM: None; (0)
Comm. Kit:
Intrusion Alarm
Switch
False
Generator
Running
False
Common Fault
False
Low Battery
Voltage Warning
False
PIM: Not in Auto
Warning;
Comm Kit: Low
Fuel Pressure
Warning
False
TP-6844 1/13