Kohler 6VSG Service Manual page 33

Dc generator sets
Hide thumbs Also See for 6VSG:
Table of Contents

Advertisement

SiteTech Group
Genset Run Time
Genset Run Time
Genset Run Time
Genset Run Time
Genset Run Time
Genset Run Time
Genset Personality Profile
Genset Personality Profile
Genset Personality Profile
Genset Personality Profile
Genset Personality Profile
Genset Personality Profile
Genset Personality Profile
Genset Personality Profile
Genset System Configuration Genset System Voltage
Genset System Configuration Genset Power Rating
Genset System Configuration Genset Rated Current
Genset System Configuration Genset System Battery Voltage
Genset System Configuration Current Transformer Ratio
Genset System Configuration Measurement System
Genset System Configuration Display Contrast
Genset System Configuration Genset System Language
Genset System Configuration Generator Maximum Percent Capacity
Genset System Configuration Genset Fuel Type
Genset System Configuration Automatic Start Minimum Voltage
Genset System Configuration Automatic Stop Minimum Percent Load
Genset System Configuration Automatic Start Minimum Voltage Delay
Genset System Configuration Automatic Stop Minimum Load Delay
Genset Calibration
Genset Calibration
Genset Calibration
Genset Calibration
Genset Calibration
Genset Calibration
Genset Calibration
Advanced Speed Control
Advanced Speed Control
Advanced Speed Control
Advanced Speed Control
TP-6844 1/13
Parameter
Genset Controller Date Format
Genset Controller Time Format
Genset Date Time of Next Maintenance
Maintenance Period In Days
Maintenance Period Remaining
Genset Controller Clock Time Zone Offset
ECM Model
Engine Number Of Flywheel Teeth
Engine Warmed Up Temperature
Engine Cooled Down Temperature
Engine Crank Disconnect Speed
Engine Idle Speed
Engine Run Speed
Personality Installed Options
Genset Calibration Factor Voltage L1-L2
Genset Calibration Factor Voltage L2-L3
Genset Calibration Factor Voltage L1-N
Genset Calibration Factor Current L1
Genset Calibration Factor Current L3
Current Transformer Calibration At No Load
Current Transformer Calibration At Full Load
Proportional Gain
Transient Integral Gain
Derivative Gain
Slow Correction Integral Gain
Adjustment
Units
Range *
MM/DD/YYYY
or
DD/MM/YYYY
12 or 24 hr
Read Only
days
Read Only
s
Read Only
Read Only
DO NOT
CHANGE
Locked
°C/F
77–140°C
°C/F
Locked
rpm
300–1000
rpm
600–3000
rpm
1000–3900
None or 6VSG
Telecom for
comm. kit
V
24–60
kW
DO NOT
CHANGE
A
Read Only
V
12/24
Locked
English or metric
0–100
%
English
%
0–120
Natural Gas or
LPG (pulldown)
V
Read Only
%
Read Only
s
Read Only
s
Read Only
0.9–1.1
0.9–1.1
0.9–1.1
0.9–1.1
0.9–1.1
Read Only
Read Only
DO NOT
ADJUST unless
instructed by the
Kohler
Generator
Service
Department.
Section 3 Controller
Default Setting
MM/DD/
YYYY
12 Hr
N/A
365
31536000
1/1/01
12:00:00
AM
No ECM
12
90°C
102°C
750
2200
2900
6VSG:None;
Comm Kit: 6VSG
Telecom
24V = 27
36V = 40.5
48V - 54V
Auto select based
on genset model
and fuel type
12
400
English
50
English
85.0
Natural Gas
37.5
40
180
180
1.0063
0.9909
0.9427
1.000000
1.000000
3.7
170.3
Factory set per
unit.
33