Starting the measurement

To start a measurement session, hold the Reader with the infrared link aimed at the
infrared link window of the doseBadge. The Reader and doseBadge can be up to 50cm
apart. Press the Run key. The Reader will program the start time and date into the
doseBadge.
The Reader will show the status of the communication between the doseBadge and the
Reader on the display.
When the doseBadge is running (and making a measurement), the indicator will flash
quickly to indicate that the unit is operating.
The doseBadge can now be left on the wearer. The wearer should be instructed to avoid
knocking the badge as this can affect the Peak measurements and add to the noise
dose.

Using the RC:101A Keyfob Remote Control

The doseBadge can also be started using the RC:101B Keyfob Remote Control. Point
the Keyfob at the doseBadge infrared window and press the Run button. The doseBadge
will start in the same way as described above for the Reader unit.
CR:112A & CR:112AIS doseBadge User Manual
Do not move the Reader away from the doseBadge until
the indicators show in the doseBadge.
An indicator will show in the badge window for up to 2
seconds to show that it has received the message and
started running. If an indicator does not show then try
again.