PI P-725 CDE2 Series User Manual

PI P-725 CDE2 Series User Manual

Focus scanners for microscope objectives

Advertisement

Quick Links

User Manual
P725UM0001EN, applies to P-725.xCDE2
CBo/KSch, 4/1/2022
P-725.xCDE2
PIFOC Focus Scanners for Microscope Objectives
Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,
www.pi.ws

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P-725 CDE2 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PI P-725 CDE2 Series

  • Page 1 User Manual P725UM0001EN, applies to P-725.xCDE2 CBo/KSch, 4/1/2022 P-725.xCDE2 PIFOC Focus Scanners for Microscope Objectives Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de, www.pi.ws...
  • Page 2: Table Of Contents

    Cleaning the P-725............................. 20 Disassemble the P-725 and Thread Adapter ..................... 21 Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 2 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 3 Torque for Stainless Steel Screws (A2-70) ......................27 Pin Assignment ..............................28 Old Equipment Disposal Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 3 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 4: About This Document

     Precautionary measures to avoid the risk. INFORMATION Additional information that can affect your application. Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 4 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 5: Figures

    5. Click the desired manual and fill out the inquiry form. The download link will then be sent to the email address entered. Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 5 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 6: Safety

    It is only possible to use the P-725 as intended when it is completely mounted and connected. It must be operated with a suitable controller that is available from PI (p. 10). The controller is not included in the scope of delivery of the P-725.
  • Page 7  Do not use extension cables. If you need longer cables, contact our customer service department (p. 23). Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 7 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 8: Product Description

    P-725.14M P-725.14L P-725.14S Refer to "Optional Accessories" (p. 11) for details. Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 8 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de, www.pi.ws...
  • Page 9: Product View

    Warning sign "Pay attention to the manual!" Old equipment disposal (p. 28) Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 9 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 10: Scope Of Delivery

    TCP/IP-, USB- and RS-232 interface  To order, contact the customer service department (p. 23). Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 10 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 11: Optional Accessories

    P-725.14L Thread adapter for objective, M34 x 1, aperture diameter 28 mm Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 11 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 12: P-725.Xxs Spacers

    (p. 23). 4. Keep all packaging materials in case the product needs to be returned. Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 12 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 13: Installing

    The supplied M4 protective earth conductor screw set for connecting the protective  earth conductor (p.10) Suitable screwdriver  Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 13 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de, www.pi.ws...
  • Page 14: Mounting The P-725

     You have read and understood the safety precautions (p. 6).  The P-725 is not connected to the electronics. Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 14 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 15: Mounting The P-725 Using The Mounting Holes In The Base Body (Optional)

     Note that only the P-725.xxL thread adapter on the objective side is required when mounting the P-725 using the mounting holes in the base body. Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 15 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 16 5. Screw the objective from below into the thread adapter on the objective side of the P-725. Do not exceed the maximum torque of 0.6 Nm. Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 16 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 17: Mounting P-725.Xxs Spacers

     Connect the plug of the P-725 to the corresponding socket on the electronics (refer to the user manual for the electronics). Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 17 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 18: Starting And Operating

     Set the piezo voltage to 0 V on the controller if the P-725 is not used but should remain switched on to ensure the temperature stability. Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 18 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 19: Starting And Operating The P-725

    If the connecting cable of the P-725 is accidentally pulled out of the electronics during  operation Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 19 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 20: Maintenance

    In open-loop operation:  Set the piezo voltage to 0 V on the electronics. Discharging a P-725 not Connected to the Electronics  Connect the P-725's voltage plug to the switched-off electronics from PI for 10 seconds. Maintenance NOTICE Misalignment from loosening screws! The P-725 is maintenance-free and precision adjusted.
  • Page 21: Disassemble The P-725 And Thread Adapter

    Screw the objective out before removing. Hold the P-725 firmly when you loosen the upper thread adapter. Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 21 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 22 4. Use the wide side of the key tool to unscrew the thread adapter on the microscope side. Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 22 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 23: Technical Data

    User Manual P725UM0001EN, applies to P-725.xCDE2 CBo/KSch, 4/1/2022 Customer Service For inquiries and orders, contact your PI sales representative or send us an email (service@pi.de).  If you have questions concerning your system, provide the following information: − Product and serial numbers of all products in the system −...
  • Page 24 10 to 70 °C 10 to 70 °C The resolution of the system is limited only by the noise of the amplifier and the measuring technology because PI piezo nanopositioning systems are free of friction. All specifications based on room temperature (22 °C ±3 °C).
  • Page 25: Maximum Ratings

    * The specifications apply to room temperature (22 °C ± 3 °C). The specifications can deviate outside of this range. Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 25 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 26: Dimensions

    P-725.1CDE2 and P-725.4CDE2, dimensions in mm (please order adapters and spacers separately). Note that a comma is used in the drawings instead of a decimal point. Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 26 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de,...
  • Page 27: Torque For Stainless Steel Screws (A2-70)

    0.4 Nm 0.15 Nm 0.2 Nm M1.6 0.06 Nm 0.12 Nm Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Deutschland Page 27 / 28 Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.de, www.pi.ws...
  • Page 28: Pin Assignment

    Dispose of your old equipment according to international, national, and local rules and regulations. To fulfill the responsibility as the product manufacturer, Physik Instrumente (PI) GmbH & Co. KG undertakes environmentally correct disposal of all old PI equipment made available on the market after 13 August 2005 without charge.