4. Transport, packaging and storage / 5. Commissioning, operation
Permissible conditions at the place of storage:
Storage temperature: -20 ... +70 °C [-4 ... +158 °F]
Humidity: < 90 % rel., non-condensing

5. Commissioning, operation

Personnel: Skilled personnel
Tools: Open-ended spanner
CAUTION!
Prior to commissioning, the digital pressure gauge must be subjected to a visual
inspection.
Only use the digital pressure gauge if is in perfect condition with respect to safety.
Required tool: Open-ended spanner (spanner width 27 mm)
WARNING!
Physical injuries and damage to property and the environment caused by
hazardous media
Upon contact with hazardous media (e.g. oxygen, acetylene, flammable or toxic
substances), harmful media (e.g. corrosive, toxic, carcinogenic, radioactive), and also with
refrigeration plants and compressors, there is a danger of physical injuries and damage to
property and the environment.
Should a failure occur, aggressive media with extremely high temperature and under high
pressure or vacuum may be present at the instrument.
For these media, in addition to all standard regulations, the appropriate existing codes
or regulations must also be followed.
Wear the requisite protective equipment.