This signal is displayed via a digital indicator. Subject to technical modifications. ■ The DG-05 is a digital pressure gauge and Full scale (FS) accuracy is ±0.5% based on Further information: ■ the upper limit of the measurement range.
Special operating conditions require further appropriate knowledge, e.g. of aggressive media. 3.2 Intended use The DG-05 digital pressure gauge acts as the display for the applied pressure. The 3.4 Labelling, safety marks pressure value is displayed via a digital indicator.
Before putting it back into operation, wait for the instrument temperature and the room temperature to equalise. When fitting the DG-05 digital pressure gauge, the force required to mount / seal ■ must not be applied through the case, but only through the spanner flat provided for 4.2 Packaging and storage...
Page 5
5.3 Operating the DG-05 digital pressure gauge Turning on (ON) CAUTION! ▶ Press ON/OFF button to power up the DG-05. ON/OFF The zero-point correction sets the current actual value to zero. In order to exclude faulty measurements, ensure no system pressure is being applied Below sequence will be displayed during boot up.
Page 6
UNIT ON/OFF The DG-05 auto power-off can be set as 5, 15, 30, 60 minutes. For the exchange of the instrument chapters 8 “Dismounting, return and disposal” and 5 “Commissioning, operation” must be observed.
Page 7
Strictly observe the following when shipping the instrument: tionary measures. All instruments delivered to WIKA must be free from any kind of hazardous substances (acids, bases, solutions, etc.) and must therefore be cleaned before being returned. For information on returning the DG-05 digital pressure gauge see chapter WARNING! “8.2 Return”...
Page 8
0 … 16 0 … 25 Process connection 0 … 40 1/4" NPT (M) per ASME B1.20.1 Thread size 0 … 100 Others through adaptors 0 … 250 1,000 0 … 400 1,200 WIKA operating instructions, Digital pressure gauge, model DG-05...