OVERHEAT PROTECTION

When overheating occurs, the cooking zone will display error code:
E6 – Overheating of cooking zone
E9 – Overheating of IGBT sensor
The induction hob will stop heating and no power will be delivered to the cooking
zone.
Let the cooking zone cool down before using.

OVERFLOW PROTECTION

When the liquid flows to the control panel, the hob will automatically shut down
within 10 seconds.
To restart, turn off the power and wipe the area with a clean towel before using.

POWER MANAGEMENT

Power sharing function limits the maximum power used. The maximum available
power (preset) is shared between the cooking zones. If all zones are turned on, the
power management will not allow all zones to operate at full power but will alternate
the power among all zones so the total power will be equal to the preset maximum
power. The change will be visible on power level displays. The last command given to
a cooking zone takes priority on the power setting.