Installing and connecting the device
3.1 Preparing for installation
3.1.3
Permitted mounting positions
The device may be mounted in the following positions:
• Standard position: Vertical installation in horizontal format
For vertical installation in horizontal format, the following ambient temperatures are
permitted:
• Inclined installation in horizontal format with a vertical inclination of maximum ±45 °
For inclined installation in horizontal format, the following ambient temperatures are
permitted:
22
Maximum ambient temperature at the device
Load
7" and10"
M.2 Module - 0W
50 °C
M.2 Module - 5W
45 °C
Maximum ambient temperature at the device
Load
7" and10"
M.2 Module - 0W
50 °C
M.2 Module - 5W
45 °C
12" and 15"
19", 22" and 24"
50 °C
45 °C
50 °C
45 °C
12" and 15"
19", 22" and 24"
45 °C
40 °C
45 °C
40 °C
Operating Instructions, 08/2021, A5E50059956-AA
Comment
The device enclosure fulfills the
requirement of a fire protection
enclosure.
Comment
The device enclosure fulfills the
requirement of a fire
protection enclosure.
SIMATIC IPC277G