Technical specifications
8.4 Technical data
Electromagnetic compatibility
Radiation Emission (Enclosure port)
in accordance with IEC 61000-6-3
+ A1/ CAN/CSA-CISPR 22:10
Immunity with regard to
conducted interference on the
supply lines
Noise immunity on signal lines
Immunity to discharges of static
electricity
Immunity to RF interference
Conducted Emission (Low voltage
DC mains port), in accordance with
IEC 61000-6-3 + A1
Conducted
Emission(Telecommunications/Net
work Port),
in accordance with IEC 61000-6-3
+ A1
84
30 to 230MHz: 30dB(uV/m) quasi-peak(10m distance)
230 to 1000MHz: 37dB(uV/m) quasi-peak(10m distance)
1 to 3 GHz: 76dB(uV/m) peak; 56dB(uV/m) average (3m
distance)
3 to 6 GHz: 74dB(uV/m) peak; 54dB(uV/m) average (3m
distance)
Burst: ± 2 kV (5 kHz /100 kHz) in accordance with IEC 61000-
4-4;
Surge: ± 1kV line to line, ±2 kV line to earth in accordance
with IEC 61000-4-5;
Burst:
± 1 kV (5 kHz /100 kHz) in accordance with IEC 61000-4-4;
Length of signal port extension cable < 30 m;
± 2 kV (5 kHz /100 kHz) in accordance with IEC 61000-4-4;
Length of signal port extension cable ≥ 30 m;
Surge:
±2kV shielding-to-earth in accordance with IEC 61000-4-5;
Length of signal port extension cable ≥ 30 m;
± 6 kV contact discharge in accordance with IEC 61000-4-2
± 8 kV air discharge in accordance with IEC 61000-4-2
Radiation Immunity (according to IEC 61000-6-2)
80 MHz to 2GHz
10 V/m, 80 % AM (1 kHz)
2 GHz to 6.0 GHz
3 V/m, 80 % AM (1 kHz)
Conducted Immunity (according to IEC 61000-4-6)
10 kHz to 80 MHz: 10 V, 80% AM (1kHz)
0.15 to 0.5 MHz / 79 dB (μV) Q, 66 dB (μV) M
0.5 to 30 MHz / 73 dB (μV) Q, 60 dB (μV) M
0.15 to 0.5 MHz:
84 dB(μV) to 74 dB(μV) Q
74 dB(μV) to 64 dB(μV) M
0.5 MHz to 30 MHz:
74 dB(μV) Q / 64 dB(μV) M
Operating Instructions, 08/2021, A5E50059956-AA