TROUBLESHOOTING - SOLAR ECU
LCD Display References
Meaning
LCD MSG
Error Messages
Er PANEL
Indicates that the voltage being provided from the solar panel is too low.
LOW
ER PANEL
Indicates that the voltage being provided from the solar panel is too High.
HIGH
ER SOLAR
Indicates that there is no voltage being provided from the solar panel.
NO PANEL
ERR NO
Solar board can't detect a solar gate operator.
Sol UNIT
ERR CHRG
Indicates the Solar Panel voltage is high or potential problem with the Solar
Charger.
HIGH
ERR BAT
The battery is low
LOW
ERR FUSE
15 Amp motor fuse is blown on the Primary or Single Control Board.
15 AMP
ERR FUSE
15 Amp motor fuse is blown on the Secondary Module.
15A
S
ERR REFV
One, or more, of the internal reference voltages are incorrect.
WRONG
ERR SENS
There is a problem with the required monitored sensor(s) connected
to the "UL" and/or "Re-Open" input terminals (pg 16, 20-21).
UL
RO
ERRLIMIT
There is a problem with the Limit Switches or Wires.
OPN+CLS
5 0