Initial Settings

NOTE:
Installing a shunt, or jumper, on the pins will activate the feature.
"Auto Open" - Power Failure Option
Opens the gate automatically during
power failure. Resumes normal operation
when power is restored.
!
This Feature is disabled on Solar ECU.
"Fail Safe/Secure"
During power failure, determines the
force required to manually move the gate.
• Fail Safe Mode:
By removing the wire-jumper plug from
the "Fail Safe/Secure" connector:
The gate can move manually with a
relatively low amount of force.
• Fail Secure Mode:
By inserting the wire-jumper plug into
the "Fail Safe/Secure" connector:
The gate will require more effort to
manual move.
VIKING TECHNICAL SUPPORT 1.800.908.0884
CONTROL BOARD SETUP
"Last Open" - Power Failure Option
Opens the gate automatically when the
battery backup voltage is critically low.
"Pre-Warning"
Initiates two options for an
audible or visual warning 3 seconds prior
to gate motion and will continue:
1. Until gate reaches closed limit:
"Magnetic Lock" terminals provide a
contact between "COM" and "N.O.".
2. Until gate reaches either limit:
"AUX. PWR" terminals provide 24VDC.
"Sync"
Used only in conjunction with
Barrier Arm Operators. Activating
this feature allows for synchronized
operation with Barrier Arm Operators.
See page 35.
"EXT"
Available for future developments.
2 5