ELECTRICAL INSTALLATION - STANDARD ECU
Motor Cable - Primary (Single)
NOTE:
The Single Electronic Control Unit is equipped to operate a single gate motor only,
and does not include a Secondary Module. The steps described on page 21 do not apply
for this type of application.
STEP 3
Primary Motor:
a. Connect motor cable to the Motor
Connector at the Primary Control
Board as illustrated, according to
the printed color code.
b. Attach the grounding wire, non
insulated, to the Board Mounting
Plate using the screw provided.
STEP 4
Primary Open Left or Open Right:
Place the terminal block in the proper location for the gate opening direction.
• "OPEN RIGHT" Connector if the gate opens to the INSIDE (pull to open).
• "OPEN LEFT" Connector if the gate opens to the OUTSIDE (push to open).
2 0
OPEN LEFT
OPEN LEFT
Open
Outside
Inside
OPEN RIGHT
OPEN RIGHT
Open
3a
3b
Open
Open
VIKING TECHNICAL SUPPORT 1.800.908.0884
Primary Motor
BLUE
BLACK
NOT CONNECTED
YELLOW
BROWN
RED
ORANGE