Parameters - Siemens SIMATIC ET 200eco PN M12-L Equipment Manual

Hide thumbs Also See for SIMATIC ET 200eco PN M12-L:
Table of Contents

Advertisement

Modbus TCP
6.1 Functions/parameters/address space
6.1.2

Parameters

The table below shows the parameters for the I/O device digital inputs
DI 8x24VDC M12-L 8xM12.
Table 6- 1
Configurable parameters and their defaults (GSD file)
Parameters
Dual assignment of the sock-
et
Diagnostics: Undervoltage
1L+
Diagnostics: Short-circuit
Diagnostics: Wire break de-
tection and alarm
Input delay
Hardware interrupt on rising
edge
Hardware interrupt on falling
edge
* = Short-circuit monitoring of the socket takes place once via Pin 1 (1L+) and Pin 3 (1M).
46
Value range
Disable
Enable
Disable
Enable
Disable
Enable
Disable
Enable
0.05 ms
0.1 ms
0.4 ms
0.8 ms
1.6 ms
3.2 ms
12.8 ms
20 ms
Disable
Enable
Disable
Enable
Default
Disable
Channel group
Disable
Channel
Disable
Channel/channel group*
Disable
Channel
3.2 ms
Channel
Disable
Channel
Disable
Channel
I/O device digital inputs DI 8x24VDC M12-L 8xM12 (6ES7141-6BG00-0BB0)
Equipment Manual, 02/2022, A5E46570417-AC
Effective range with configuration
software, for example, MFCT