Tubular motor: GEIGER SOLIDline Motor control: SOLIDline ZIP-Perfection (GU45...-E11) for screens with ZIP guidance Original-Montage- und Betriebsanleitung Original assembly and operating instructions Notice originale de montage et d’utilisation Instrucciones originales de instalación y funcionamiento Istruzioni originali di installazione e funzionamento...
1. General information Dear customer, By purchasing a GEIGER motor you have decided on a quality product from GEIGER. Thank you very much for your decision and the confidence placed in us. Before you put this drive into operation please observe the following safety instructions. It serves for the prevention of danger and for the avoidance of personal injury and damage to property.
- E11 Motor control Motor head Torque in Nm Motor diameter GEIGER universal drive 4. Safety instructions ATTENTION: Important safety instructions. For personal safety, it is important to follow these instructions. Please keep these instructions for future reference. f Do not allow children to play with stationary controls. Keep remote controls away from children.
A plug for the disconnection of the motor from the power supply must be accessible after installation. f Damaged connecting cables must be replaced by GEIGER connecting cables of the same type. f The device must be mounted as described in the installation instructions. Fixations shall not be made with adhesives since they are regarded as unreliable.
– Place the motor into the existing engine bearer and lock – Place the motor in a compatible engine bearer with clip system and lock with spring or rotating lever The GEIGER SOLIDline motor is suitable for shaft diameters from 50 mm! www.geiger.de...
Article Number / GEIGER setting switch M56F152 with service terminal (D), 5 wires, SMI compatible M56F153 with service terminal (CH), 5 wires, SMI compatible M56F154 with service terminal (D), 4 wires Gerhard Geiger GmbH & Co. KG | 100W2580 V000 0322...
4. The programming process is then completed and the motor switches to normal operation. The direction of rotation of the motor is automatically assigned to the upper and lower end positions. The end positions are stored only after the second torque switch-off for each end position. www.geiger.de...
The drive returns to the delivery state. 15. Change/delete the end position In order to change or delete the end positions, a new programming must be started (see «Setting of the end stops»). Gerhard Geiger GmbH & Co. KG | 100W2580 V000 0322...
(total weight), friction, etc. for each installation type and size, as there might be important variations. Ø100 Ø85 6 Nm 10 Nm Ø78 Ø63 End slat weight [kg] www.geiger.de...
• The motor became too hot and has the motor breaks down and switched off. no longer responds. Try it again after a cooling time of about 15 min. 20. Maintenance The drive is maintenance-free. Gerhard Geiger GmbH & Co. KG | 100W2580 V000 0322...
The average sound pressure level data are intended for guidance only. The values were determined by GEIGER at a distance of 1 m, with a hanging motor at idle speed and averaged over 10 seconds. There is no reference to any specific test standard.