GEIGER SOLIDline ZIP-Perfection GU45 E11 Series Original Assembly And Operating Instructions

Advertisement

Quick Links

Tubular motor:
GEIGER SOLIDline
Motor control:
SOLIDline ZIP-Perfection (GU45...-E11)
for screens with ZIP guidance
Original-Montage- und
DE
Betriebsanleitung
Original assembly and
EN
operating instructions
Notice originale de montage
FR
et d'utilisation
Instrucciones originales de
ES
instalación y funcionamiento
Istruzioni originali di installazione
IT
e funzionamento
www.geiger.de
EN
1
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SOLIDline ZIP-Perfection GU45 E11 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GEIGER SOLIDline ZIP-Perfection GU45 E11 Series

  • Page 1 Tubular motor: GEIGER SOLIDline Motor control: SOLIDline ZIP-Perfection (GU45...-E11) for screens with ZIP guidance Original-Montage- und Betriebsanleitung Original assembly and operating instructions Notice originale de montage et d’utilisation Instrucciones originales de instalación y funcionamiento Istruzioni originali di installazione e funzionamento...
  • Page 2: Table Of Contents

    1. General information Dear customer, By purchasing a GEIGER motor you have decided on a quality product from GEIGER. Thank you very much for your decision and the confidence placed in us. Before you put this drive into operation please observe the following safety instructions. It serves for the prevention of danger and for the avoidance of personal injury and damage to property.
  • Page 3: Intended Use

    - E11 Motor control Motor head Torque in Nm Motor diameter GEIGER universal drive 4. Safety instructions ATTENTION: Important safety instructions. For personal safety, it is important to follow these instructions. Please keep these instructions for future reference. f Do not allow children to play with stationary controls. Keep remote controls away from children.
  • Page 4: Safety Instructions For Assembly

    A plug for the disconnection of the motor from the power supply must be accessible after installation. f Damaged connecting cables must be replaced by GEIGER connecting cables of the same type. f The device must be mounted as described in the installation instructions. Fixations shall not be made with adhesives since they are regarded as unreliable.
  • Page 5: Installation Instructions

    – Place the motor into the existing engine bearer and lock – Place the motor in a compatible engine bearer with clip system and lock with spring or rotating lever The GEIGER SOLIDline motor is suitable for shaft diameters from 50 mm! www.geiger.de...
  • Page 6: Information For The Specialist Electrician

    Article Number / GEIGER setting switch M56F152 with service terminal (D), 5 wires, SMI compatible M56F153 with service terminal (CH), 5 wires, SMI compatible M56F154 with service terminal (D), 4 wires Gerhard Geiger GmbH & Co. KG | 100W2580 V000 0322...
  • Page 7: Starting The Setting Modes

    4. The programming process is then completed and the motor switches to normal operation. The direction of rotation of the motor is automatically assigned to the upper and lower end positions. The end positions are stored only after the second torque switch-off for each end position. www.geiger.de...
  • Page 8: Manual Programming Of The End Positions

    The drive returns to the delivery state. 15. Change/delete the end position In order to change or delete the end positions, a new programming must be started (see «Setting of the end stops»). Gerhard Geiger GmbH & Co. KG | 100W2580 V000 0322...
  • Page 9: Obstacle Detection

    (total weight), friction, etc. for each installation type and size, as there might be important variations. Ø100 Ø85 6 Nm 10 Nm Ø78 Ø63 End slat weight [kg] www.geiger.de...
  • Page 10: Referencing / End Position Correction

    • The motor became too hot and has the motor breaks down and switched off. no longer responds. Try it again after a cooling time of about 15 min. 20. Maintenance The drive is maintenance-free. Gerhard Geiger GmbH & Co. KG | 100W2580 V000 0322...
  • Page 11: Declaration Of Conformity

    Gerhard Geiger GmbH & Co. KG Schleifmühle 6 | D-74321 Bietigheim-Bissingen Phone +49 (0) 7142 9380 | Fax +49 (0) 7142 938 230 | info@geiger.de | www.geiger.de Sitz Bietigheim-Bissingen | Amtsgericht Stuttgart HRA 300591 | USt-IdNr. DE145002146 Komplementär: Geiger Verwaltungs-GmbH | Sitz Bietigheim-Bissingen | Amtsgericht Stuttgart HRB 300481 Geschäftsführer: Roland Kraus | WEEE-Reg.-Nr.
  • Page 12: Technical Data For Solidline Motors

    The average sound pressure level data are intended for guidance only. The values were determined by GEIGER at a distance of 1 m, with a hanging motor at idle speed and averaged over 10 seconds. There is no reference to any specific test standard.

Table of Contents