DC to DC Converter Description
Front
M12 K-Code Male
DC Input
Rear
M12 K-Code Female
DC Output
System / NVR Description
M12 K-Code Male
DC Input
PIN
PIN 1
GND
PIN 2
DC_IN
PIN 3
GND
PIN 4
IGN_IN
PIN 5 (PE)
CHASSIS GND
Note: SKU A: DC 32~96V
SKU B: DC 24~36V
SKU C: DC 72~110V
PIN
PIN 1
IGN_OUT
PIN 2
MCU_PG
PIN 3
DC 54V Output
PIN 4
GND
PIN 5 (PE)
CHASSIS GND
PIN
PIN 1
GND
PIN 2
DC_IN
PIN 3
MCU_PG
PIN 4
IGN_IN
PIN 5 (PE)
CHASSIS GND
Note: DC_in, below 44V without PoE power support
DC_in, above 45V enable PoE power support
84
Description
Primary Ground
DC Power Input (Isolated)
Primary Ground
Power ON Trigger form car ignition ON
Chassis Ground
Description
Adapter Ignition on Trigger Signal
MCU Power_good detect pin (Isolated)
54V Output
Secondary Ground (S_G for NVR)
Chassis Ground
Description
Signal Ground
DC Power Input (from DC converter, 52V)
System Power Good Status
(without isolated because EMI solution)
Ignition on Trigger Form Adapter
(Ignition voltage support: 12V or 24V)
Chassis Ground