PTT-100V Operating Instructions Ver.4.03E
6
Press
measurement result as in the right illustration.
If the results meet the value set at "<MENU 1>
PATTERN SETTING," the unit will proceed to
perform normal operations.
If the results fall the set value, ERROR is
displayed and the unit will cease to operate.
When the grip is moving, please be
Caution
careful not to pinch your fingers.
TIPS
Press
inspection.
After the
button is pressed:
       a) 
The load applied to the load-cell is
adjusted 0.
       b) 
The DC motor starts moving and each
parameters such as displacement and
maximum peel strength will be
displayed in real time.
       c) 
The machine stops measuring when
there is no peel tensile load.
       d) 
The test result will be shown on the
display and then the grip returns to the
set position automatically.
TIPS
When the test mode is set manual,
the grip does not stop until it
reaches to the end.
Press
inspection.
When the return mode is set OFF,
the grip does not return
automatically after finishing the
operation.
When the error occurs, the grip
does not return automatically.
30