ELECTRICAL / HEATER ASSEMBLY

Place CB Box on the floor for easy access.
19.
Remove the cover to access the electrical
connections.
1
2
3
Note: All the low voltage connections have unique connectors.
1- Bluetooth Power (3 pin from Bluetooth sound bar (optional))
2- Room Temp Sensor (4 pin from wall)
3- High Limit (2 pin from heater)
4- Control (RJ 11 from wall)
5- Lights (RJ 45 from wall)
Green = ground
Black = L1 (hot)
White = N (neutral)
NOTE: A GFCI (Ground Fault Interrupt Circuit) device is not required by NEC. A GFCI may be installed
if required by local codes but will nuisance trip during use of the product.
CAUTION: Loose wire connections can cause heat damage to wires, terminal blocks, and other
components and may void the warranty.
21. Connect wires from power cord from outside the room to the lower terminal block labeled L1, N, and
Gnd.
22. Connect wires from the heater to upper terminal block labeled T1, T2, and Gnd to the sauna heater.
23. Install the CB Box to the back wall. Use the two spacing blocks
provided as a guide to find the lower left corner of the box to wood
corner trim on wall.
Note: If the mounting holes of CB box line up with a groove in the
wall, move the box left or right so they line up on a solid portion of the
tongue and groove.
71-0163
Rev. 01
20.
into the CB Box according to the picture and
installation manual.
4
5
Page 8
Connect all the quick connections
4215-138
09/07/2021