Cardinal SB600 Installation And Technical Manual

Cardinal SB600 Installation And Technical Manual

Remote display

Advertisement

Quick Links

SB600
Remote Display
Installation and Technical Manual
(includes SB600RI with Remote Input)
I
3601-0756-0M Rev D • SB600

Advertisement

Table of Contents
loading

Summary of Contents for Cardinal SB600

  • Page 1 SB600 Remote Display Installation and Technical Manual (includes SB600RI with Remote Input) 3601-0756-0M Rev D • SB600...
  • Page 2 3601-0756-0M Rev D • SB600...
  • Page 3: Table Of Contents

    Page 6 Mounting the SB600 …………………………………….……….…….….… Page 6 Wall Mounting ……..…….….… Page 7 Mounting on Cardinal Scale’s 10 ft or 12 ft High Pole ….….… Page 10 Accessing SB600 Controller Board and AC Power Connections …..……………....….….…….….… Page 11 AC Power Connection …..………………....….…..…...
  • Page 4 Page 41 Parts List for Section D-D, Detail F, Detail K, and Detail M Views PRECAUTIONS Before using this instrument, read this manual and pay special attention to all "WARNING" symbols: ELECTRICAL STATIC IMPORTANT WARNING SENSITVE 3601-0756-0M Rev D • SB600...
  • Page 5 Seller is not able to guarantee the result of any procedure contained herein. Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures. Persons engaging in the procedures do so entirely at their own risk. 3601-0756-0M Rev D • SB600...
  • Page 7: Introduction

    INTRODUCTION Thank you for your purchase of our Cardinal SB600 Remote Display. It was built with Cardinal quality and reliability at our factory in Webb City, Missouri. This manual will guide you through the installation, and operation of your display. Please read it thoroughly before attempting to install your display.
  • Page 8: Features

    • Option Card). Optional • Remote inputs to control the traffic lights on the SB600 by a remote device. NOTE: Requires Model SB600RI with Remote Input. INSTRUMENT COMPATIBILITY Utilizing the Auto-Learn feature, the SB600 display can be driven by the following Cardinal weight indicators and by most weight indicators from other manufacturers.
  • Page 9: Multiple Displays

    MULTIPLE DISPLAYS The SB600 display has been designed to be linked or daisy chained to other SB600 displays allowing multiple lines of weight data to be displayed while being driven by a single serial port on the weight indicating instrument. Typical applications might consist of three displays showing Gross, Net, and Tare weights from a single indicator or four displays showing the weight from each of three platforms and a total weight also from a single weight indicator.
  • Page 10: Site Preparation

    SITE PREPARATION Electrical Power The SB600 and SB600RI remote display has been designed to operate from 90 to 130 VAC at 50/60 Hz, 100 watts maximum. The SB600EU and SB600UK remote display has been designed to operate from 180 to 264 VAC at 50/60 Hz, 100 watts maximum.
  • Page 11: Installation

    INSTALLATION Unpacking Before beginning the installation of your SB600 remote display, make certain it has been received in good condition. Carefully remove the display from the shipping carton and inspect it for any evidence of damage (such as exterior dents or scratches) that may have taken place during shipment.
  • Page 12: Mounting The Sb600

    INSTALLATION, CONT. Mounting the SB600 The SB600 display includes a two-piece bracket that is used to mount it on a wall or other flat vertical surface. The two-piece bracket along with two purchased U-bolts can also be used to mount the SB600 to Cardinal Scale’s 4.5-inch OD 10-foot-high mounting pole with base plate (8100-D028-0A), or 12-foot high mounting pole with base plate (8100-D028-1A).
  • Page 13: Mounting On Cardinal Scale's 10 Ft Or 12 Ft High Pole

    Figure No. 5 – SB600 Mounted on Cardinal Pole The SB600 pole bracket has been designed with four 0.55-inch holes, spaced to accept the two 4.5-inch Clamping U-bolts to secure the bracket to the pole. The U-bolts included with the POLE-120 and POLE-144 are zinc-plated steel that complements the stainless steel finish of the SB600 Pole Bracket.
  • Page 14 Figure No. 7 – Install Pole Bracket on Pole IMPORTANT! Visually check both sides of the pole to ensure the U-bolts are completely tightened against the pole. Figure No. 8 – Visually Check that U-bolts are Tight Against Pole 3601-0756-0M Rev D • SB600...
  • Page 15 INSTALLATION, CONT. 3. With the pole installed, align the bracket on the back of the SB600 with the bracket on the pole. Lower the SB600 until the top of the two brackets are flush with each other. Figure No. 9 – Align Brackets and Slide Together 4.
  • Page 16: Accessing Sb600 Controller Board And Ac Power Connections

    INSTALLATION, CONT. Accessing the SB600 Controller Board and AC Power Connections Referring to Figure No. 12, continue by removing the twelve acorn nuts from the Bottom Access Panel, and fully lower the panel exposing the controller board and the AC power terminal block.
  • Page 17: Ac Power Connection

    • For permanent installations or non-reversible plugs, a single-pole protection device to interrupt L1 (H) must be provided. • Some plugs/socket systems are reversible (L & N). In this case, an external dual protection device must be provided. 3601-0756-0M Rev D • SB600...
  • Page 18: Sb600 Controller Board

    CL RX- CL RX+ CL TX- CL TX+ Figure No. 14 Jumper Settings Table 232 DAISY CHAIN 422 DAISY CHAIN 422 DAISY CHAIN - END NODE 485 ADDRESSED 485 ADDRESSED END NMODE 20mA CURRENT LOOP 3601-0756-0M Rev D • SB600...
  • Page 19: Status Leds And Display

    S1 = (+) Used during programming to increment to the next parameter value. S2 = (MODE) Press to begin Setup and Configuration mode. During setup, press to advance to the next setup parameter. S3 = (−) Used during programming to decrement to the previous parameter value. 3601-0756-0M Rev D • SB600...
  • Page 20: Serial Cable Installation

    Finger-tighten only! DO NOT USE TOOLS! 6. Install Receive mode jumper J2 and J6 for RS-232 operation. Remove current loop mode jumper, J1. SB600 Internal circuitry shown. Figure No. 15 3601-0756-0M Rev D • SB600...
  • Page 21: 20Ma Current Loop

    5. After all terminations have been made, remove any excess cable from the enclosure and securely tighten the cable gland connector. Finger-tighten only! DO NOT USE TOOLS! 6. Install the Receive mode jumper J1. Remove J2 and J6. SB600 Internal circuitry shown. Figure No. 16 3601-0756-0M Rev D • SB600...
  • Page 22: Rs485/422

    NOTE: The last display on the RS422 bus must have terminating jumpers installed, and the display in the middle of the bus must have terminating jumpers removed. 7. Install Receive mode jumper J2. Remove J1 and J6. SB600 Internal circuitry shown. Figure No. 17 3601-0756-0M Rev D • SB600...
  • Page 23: Current Cardinal Indicators 20Ma Current Loop Connections

    SERIAL CABLE INSTALLATION, CONT. CURRENT Cardinal Indicators 20mA Current Loop Connections 185/185B (Serial RS-232 Only) RS-232 ONLY SB600 P6, TX P6, RS232 RXD P6, GND P6, GND 190/190A (with 190-RS232 Option Card) CARD (PASSIVE) SB600 P4,6 P6, CLRX- P4,7 P6, GND...
  • Page 24 SERIAL CABLE INSTALLATION, CONT. CURRENT Cardinal Indicators 20mA Current Loop Connections PORT 0 (ACTIVE) SB600 P20,10 P6, CLRX+ P20,8 P6, CLRX- PORT 1 (ACTIVE) SB600 PORT 1 (PASSIVE) SB600 P20, 3 P6, CLRX+ P20, 4 P6, CLRX- P20, 4 P6, CLRX-...
  • Page 25: Legacy Cardinal Indicators 20Ma Current Loop Connections

    SERIAL CABLE INSTALLATION, CONT. LEGACY Cardinal Indicators 20mA Current Loop Connections 205, 210, 210FE, 212/212X, 212G/212GX (without USB) PORT 1 SB600 PORT 2 SB600 P11, 3 P6, CLRX+ P11, 6 P6, CLRX+ P11, 4 P6, CLRX- P11, 7 P6, CLRX-...
  • Page 26: Setup And Configuration

    The Setup and Configuration settings can be returned to the factory settings by entering the setup mode and then pressing and holding the MODE switch for 10 seconds. The SB600 will display DEFAULT for three seconds and then restart with the factory settings.
  • Page 27 RS485 protocol is used. • In daisy chain operation, if the address is greater than 0, the scoreboard will decrement the address and send the data out of the serial port to another daisy- chained scoreboard. 3601-0756-0M Rev D • SB600...
  • Page 28 M = Mode (G = Gross or N = Net) T = Control character for the traffic light. Valid characters for T are: For the Valid characters for T, refer to the list on the next page. 3601-0756-0M Rev D • SB600...
  • Page 29  The SB600 remote display together with the PC-based program SB Imaging Software, allows users to design custom characters or graphic images to display on the SB600. With the software installed on a PC or laptop, up to eight custom characters or graphic images can be created, and then sent to the SB600 using an RS232 cable and the built-in download capabilities of the program.
  • Page 30 This test can only complete if there is data communication coming down the line. If the SB600 cannot determine the baud rate it will display BD:FAIL. If it passes it will display BD:9600. If no data is being transmitted to the SB600 then BD:? will continue to be displayed.
  • Page 31 The messages are driven from the current-loop input on the terminal block. Note that when SWITCHED OP is enabled (set to 1 to 9), the serial input to the SB600 is disabled. Also, note that the factory default value is 0 (serial input is enabled).
  • Page 32 MODE switch to save it and advance to the next setup parameter. Values of 0 or 1 may be selected 0: NO = No suppression. The annunciator is displayed (DEFAULT) 1: YES = Suppress the annunciator display 3601-0756-0M Rev D • SB600...
  • Page 33 5: COMPUTER C: MESSAGE 6: IQ355 Utilizing the Auto-Learn feature, the SB600 display can be driven by most weight indicators. Refer to the INSTRUMENT COMPATIBILITY section of this manual. Format: <STX><Status1><Status0><Sign><XXXXXX><ETX> NOTE: <Status1><Status0> will be ignored. The SB600 will only display weight values and negative values.
  • Page 34 2: INPUT 1 GREEN = Input 1 is used and Green is default off 3: INPUT 1 AND 2 = Both inputs 1 and 2 are used Input 1 turns on Red and input 2 turns on Green 3601-0756-0M Rev D • SB600...
  • Page 35 X ranges from 0-Z (where A = 10, B = 11, …, Z = 35) SAVING Setup and configuration have been completed. The scoreboard will reset, display the red Cardinal birds, the software revision, pause, and then display the model number. 3601-0756-0M Rev D • SB600...
  • Page 36: Sb600Ri (Remote Input)

    SB600RI (REMOTE INPUT) The SB600RI with Remote Input allows a remote device to control the traffic lights on the SB600 remote display. The SB600RI saves you time, space, and money by integrating traffic control and display functions in a single remote display.
  • Page 37 SWITCH SUPPLY Figure No. 19 Cardinal Scale Mfg. Co. recommends that the cable length for all configurations of the traffic light control be kept under 300 feet (91 meters). NOTE: The traffic light control cable should be 24 AWG wire (minimum) rated at the traffic light control input voltage being used, (5V AC or DC) up to (120V AC or DC).
  • Page 38: Re-Installing The Access Panel

    (OPTION and the CARD NAME) OPT:CARDNAME after the Rev version and SB600 welcome message for 2 seconds and then display weight. During this mode, the controller board will only look for data from the option card and will ignore serial data.
  • Page 39: Start Errors And Status Messages

    START ERRORS AND STATUS MESSAGES The SB600 Remote Display is equipped with software that tests various portions of its circuitry and verifies proper operation when powered ON. Should a problem be detected, a message will be displayed. The following lists the messages displayed and their meaning:...
  • Page 40: Demo Mode

    6. When finished performing the Demo Mode, follow the instructions in the RE-INSTALLING THE ACCESS PANEL section to correctly re-install the bottom panel. NOTE: The Demo Mode can be stopped at any time by removing power to the SB600. 3601-0756-0M Rev D • SB600...
  • Page 41: Test Mode

    6. When finished performing the Test Mode, follow the instructions in the RE-INSTALLING THE ACCESS PANEL section to correctly re-install the bottom panel. NOTE: The Test Mode can be stopped at any time by removing power to the SB600. 3601-0756-0M Rev D • SB600...
  • Page 42: Part Identification

    PART IDENTIFICATION Front, Back, Section A-A, Section L-L, Section B-B, Section G-G Views 3601-0756-0M Rev D • SB600...
  • Page 43: Parts List For Front, Back, Section A-A, Section L-L, Section B-B

    LIGHT CONTROL 3601-0701-08 SB600 POLE BRACKET 3601-0708-0A SB600 BACK PANEL ASSY 3601-0717-08 SB600 LENS PLEXIGLASS .118 X 48 X 96 3601-0718-08 SB600 WIRE SUPPORT HOOK SS SHT 20 GA. 3601-0777-08 LONG CONTROL BOARD SLIDER 3601-0726-08 SB600 MOUNTING BRACKET 14 GA. SS SHT...
  • Page 44: Back Removed, Guards And Back Removed, Section C-C

    PART IDENTIFICATION, CONT. Back Removed, Guards and Back Removed, Section C-C, Detail E Views NOTE: Be sure that lens seals properly against box weldment with gaskets by ensuring gaskets are clean. 3601-0756-0M Rev D • SB600...
  • Page 45: Parts List For Back Removed, Guards And Back Removed

    3601-0804-0A PCB ASSY SB600 CONTROLLER PCB ASSY SB600RI CONTROLLER w/TRAFFIC 3601-0804-1A LIGHT CONTROL 3601-0707-08 SB600 POWER SUPPLY GUARD CR 20 GA. SHT 3601-0710-08 SB600 WIRE TRACK CR 20 GA. SHT 3601-0717-08 SB600 LENS PLEXIGLASS .118 X 48 X 96 3601-0721-08 SB600 TERMINAL BLOCK COVER 20 GA.
  • Page 46: Section D-D, Detail F, Detail K, And Detail M Views

    PART IDENTIFICATION, CONT. Section D-D, Detail F, Detail K, Detail M Views 3601-0756-0M Rev D • SB600...
  • Page 47: Parts List For Section D-D, Detail F, Detail K, And Detail M Views

    3601-0804-0A PCB ASSY SB600 CONTROLLER PCB ASSY SB600RI CONTROLLER w/TRAFFIC 3601-0804-1A LIGHT CONTROL 3601-0721-08 SB600 TERMINAL BLOCK COVER 20 GA. CR SHT 3601-0757-08 LENS RETAINER SS 20 GA. SHT 3601-0765-0A SB600 LED PANEL ASSY 3601-0766-0A TERMINAL BLOCK SWING ARM W/HW...
  • Page 48 STATEMENT OF LIMITED WARRANTY WARRANTY TERMS Cardinal Scale Manufacturing Company warrants the equipment we manufacture against defects in material and workmanship. The length and terms and conditions of these warranties vary with the type of product and are summarized below:...
  • Page 49 This warranty sets forth the extent of our liability for breach of any warranty or deficiency in connection with the sale or use of our product. Cardinal will not be liable for consequential damages of any nature, including but not limited to loss of profit, delays or expenses, whether based on tort or contract.
  • Page 50 Cardinal Scale Mfg. Co. 102 E. Daugherty, Webb City, MO 64870 USA Ph: 417-673-4631 or 1-800-641-2008 Fax: 417-673-2153 www.cardinalscale.com Technical Support: 1-866-254-8261 Printed in USA E-mail: tech@cardet.com 3601-0756-0M Rev D 12/19 3601-0756-0M Rev D • SB600...

This manual is also suitable for:

Sb600ri

Table of Contents